QOLSYS IQ Smart Socket-PG Installation Manual

Advertisement

Quick Links

Safety information

WARNING:
Follow local electrical codes and regulations in your region when performing electrical work.
Only qualified professionals should handle electrical wiring/devices.
Install and use this product in accordance with applicable electrical codes and regulations in
your region.
The device is designed for indoor use in dry locations only.
The total current limit of the device is 15 Amps. Do not exceed this limit, as it can damage the
outlet and pose a safety hazard. To avoid overloading the outlet, ensure that the combined
current of all connected devices does not exceed 15 Amps.
Keep this manual as it contains important technical data, testing, and troubleshooting
information which may be useful after installation is complete.
Do not disassemble the product or attempt to make repairs yourself. Doing so may result in
electric shock and void the limited warranty.
If you require assistance, contact our after-sales service.
Make sure to use this product together with a 15A circuit breaker.

Overview

With the IQ Smart Socket-PG, you can control your devices remotely through your control panel. For
panels that are compatible with the IQ Smart Socket-PG, see https://bit.ly/3NuoY8o.
Figure 1: Overview
D-308964 Rev 00
IQ Smart Socket-PG Installation Guide
D-308964 IQ Smart Socket-PG Install Guide
*D-308964*
D-308964

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IQ Smart Socket-PG and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for QOLSYS IQ Smart Socket-PG

  • Page 1 Make sure to use this product together with a 15A circuit breaker. Overview With the IQ Smart Socket-PG, you can control your devices remotely through your control panel. For panels that are compatible with the IQ Smart Socket-PG, see https://bit.ly/3NuoY8o.
  • Page 2 Turn the power off at the circuit breaker. Remove the existing socket and connect the new socket, see Figure Figure 2: Wiring Callout Description Line wire colored black Terminal screw marked black Terminal screw marked white IQ Smart Socket-PG Installation Guide D-308964 IQ Smart Socket-PG Install Guide...
  • Page 3 7. If the device does not automatically enroll, perform a factory reset as indicated in the Resetting the device section of the user manual. Result: The device enrolls successfully. IQ Smart Socket-PG Installation Guide D-308964 IQ Smart Socket-PG Install Guide...
  • Page 4 Signal strength LED colour and pattern Strong LED turns green and flashes 3 times Good LED turns orange and flashes 3 times Poor LED truns red and flashes 3 times IQ Smart Socket-PG Installation Guide D-308964 IQ Smart Socket-PG Install Guide...
  • Page 5 WARNING: The wiring should only be changed in accordance with applicable electrical codes and regulations in your region. WARNING: Only a qualified professional should attempt to change electrical wiring. IQ Smart Socket-PG Installation Guide D-308964 IQ Smart Socket-PG Install Guide...
  • Page 6 The IQ Smart Socket-PG is not working with certain devices • Check if the device you are trying to control with the IQ Smart Socket-PG is compatible with the IQ Smart Socket-PG. • Ensure that the device is properly plugged into the IQ Smart Socket-PG.
  • Page 7 2 and over voltages category II in non-hazardous locations, indoor only. This product is to be installed or used in accordance with local electrical codes and regulations. The IQ Smart Socket-PG is to be installed in an indoor dry location. Exposure to weather or corrosive conditions may damage the unit.
  • Page 8 QR code: Technical support Intrusion Tech support: +1- 855-476-5797 #2 or 1-800-387-3630   ©2023 Johnson Controls. All rights reserved. JOHNSON CONTROLS, TYCO and DSC are trademarks and/or registered trademarks. Unauthorized use is strictly prohibited. www.johnsoncontrols.com D-308964 IQ Smart Socket-PG Install Guide...