Summary of Contents for Radic8 VK Max

  • Page 2: Table Of Contents

    Table of Contents 1. VK Max ..............................3 2. Safety and Regulation ..........................4 2.1. Safety Information ........................... 5 2.2. Regulatory Information ........................7 3. Warranty..............................10 4. Product Overview ..........................11 4.1. Package Contents ......................... 12 4.2. VK Max ............................13 4.3.
  • Page 3: Vk Max

    Radic8 VK Max - 1_en 1. VK Max User Manual Version 1.0 For the latest version of this manual, go to radic8.com/support Copyright © 2022 Radic8 Page 3 of 37...
  • Page 4: Safety And Regulation

    VK Max - 1_en 2. Safety and Regulation Radic8 will not be responsible for any injury or loss resulting from the user’s failure to operate this device in accordance with its user manual, as updated from time to time, available on www.radic8.com...
  • Page 5: Safety Information

    • Do not immerse any part of the device in liquid or allow liquid or spray aerosols to enter the device. • In the event of smoke, unusual odors, or strange noises, switch off the device immediately and disconnect from power. Contact your local Radic8 distributor for support. Copyright © 2022 Radic8...
  • Page 6 Radic8 VK Max - 1_en • Dispose of device in accordance with local regulations. • Use biocides safely and sustainably. It is illegal to use this product in a manner other than prescribed on this label. • EU ONLY: This appliance can be used by children aged 8 years and over, as well as persons with...
  • Page 7: Regulatory Information

    VK Max - 1_en 2.2. Regulatory Information Use Environment The VK Max should be used indoors and must not be placed outdoors or anywhere that it will be exposed to water, rain, or the elements. User Proficiency The VK Max does not require any specific skills to operate. Follow the simple instructions when required to replace the filters and contact a Radic8-approved distributor when the Reactor Chamber requires replacing.
  • Page 8 Radic8 VK Max - 1_en Ingress Protection or International (or Internal) Protection. IP20 indicates protection of this device against intrusion of solid objects larger than 12mm (accidental finger contact). Transport and Storage Symbols Indicates correct upright position of the transport package.
  • Page 9 Radic8 VK Max - 1_en Normal operation of all electrical equipment in the same vicinity should be observed and verified that normal functionality is being maintained. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
  • Page 10: Warranty

    • Only Radic8 parts must be used when replacing consumables, maintaining and/or repairing this product, and failure to do so will exclude any warranty claim. • Only a Radic8-approved technician may perform any required repairs, and failure to do so will exclude any warranty claim.
  • Page 11: Product Overview

    Radic8 VK Max - 1_en 4. Product Overview VK Max brings high volume air filtration and active decontamination to large indoor spaces and mission- critical environments. Copyright © 2022 Radic8 Page 11 of 37...
  • Page 12: Package Contents

    Radic8 VK Max - 1_en 4.1. Package Contents VK Max User manual IEC power cable Remote control (plug type based on region) (batteries not included) Copyright © 2022 Radic8 Page 12 of 37...
  • Page 13: Vk Max

    Radic8 VK Max - 1_en 4.2. VK Max Tower light Signals device is operational Control panel Displays device information and provides input AC input Power input from the included C13 mains plug Back filter tray Houses back pre-filter, carbon filter, and HEPA filter Copyright ©...
  • Page 14 Radic8 VK Max - 1_en Bottom filter tray Houses bottom pre-filter, carbon filter, and HEPA filter Copyright © 2022 Radic8 Page 14 of 37...
  • Page 15: Control Panel

    Radic8 VK Max - 1_en 4.3. Control Panel PM indicator Indicates increased levels of particulate matter (PM) VOC indicator Indicates increased levels of volatile organic compounds (VOCs) Filter replacement indicator Indicates when the filters must be replaced Reactor Chamber Indicates when the...
  • Page 16 Radic8 VK Max - 1_en Down button Decreases the fan speed Power button Switches the device on or off Copyright © 2022 Radic8 Page 16 of 37...
  • Page 17: Remote Control

    Radic8 VK Max - 1_en 4.4. Remote Control Power button Switches the device on or off Mode button Displays and cycles through device information on the LCD display Up button Increases the fan speed Down button Decreases the fan speed...
  • Page 18: Installation

    Radic8 VK Max - 1_en 5. Installation Before installation, ensure you have read this manual and understand the operational requirements of the device. 1. Place the device upright in the desired location. Placement guidance: • Ensure the air intake and outlet are not obstructed.
  • Page 19 Radic8 VK Max - 1_en Remove batteries from the remote control if not in use for an extended period. 3. Retrieve the power cable from the bottom of the device. 4. Ensure the power plug is securely seated in the AC input.
  • Page 20 Radic8 VK Max - 1_en 5. Insert power plug into wall socket, ensuring correct mains voltage. 6. The device will automatically power on in Auto mode. Copyright © 2022 Radic8 Page 20 of 37...
  • Page 21 Radic8 VK Max - 1_en Copyright © 2022 Radic8 Page 21 of 37...
  • Page 22: Operation

    Radic8 VK Max - 1_en 6. Operation Turn the device on or off During installation, the device automatically powers on in Auto mode. Turn the device off or back on again by pressing the power button ( ) on the control panel or on the remote control.
  • Page 23 Radic8 VK Max - 1_en FILT – Filter replacement warning Auto and Manual Modes Move between Auto and Manual modes by pressing the Up ( ) or Down ( ) buttons on the control panel or remote control. Auto Mode Auto mode is indicated by ‘AUTO’...
  • Page 24 Radic8 VK Max - 1_en In Manual mode, the device’s fan runs at a constant speed, as set by the user. Press the Up ( ) or Down ) buttons on the control panel or remote control to adjust the fan speed.
  • Page 25 Radic8 VK Max - 1_en Sets timer for 9 hours Device will switch off after 9 hours Deactivate the tower light Press the Lamp button ( ) on the remote control or control panel to turn the tower light on or off.
  • Page 26: Maintenance

    Before handling the device to perform maintenance, lightly mist the body with an 85% alcohol-based (or equivalent) sanitizer. Maintenance of your VK Max and replacement of consumables is essential to ensure the longevity of the device. Ensure the device is switched off and disconnected from the mains before conducting any maintenance.
  • Page 27: Vk Max Filters

    Radic8 VK Max - 1_en 7.1. VK Max Filters The VK Max contains two filter trays: Back Filter Tray Bottom Filter Tray Each filter tray contains three filters: Copyright © 2022 Radic8 Page 27 of 37...
  • Page 28 Radic8 VK Max - 1_en Pre-filter Reusable. Clean regularly for efficient operation. Carbon filter Disposable. Replace when the filter replacement indicator illuminates. HEPA filter Disposable. Replace when the filter replacement indicator illuminates. The filters should always be arranged in the filter trays with the pre-filter closest to the outside of the device, the carbon filter in the middle, and the HEPA filter towards the inside of the device.
  • Page 29: Changing The Filters

    HEPA filters are overdue for replacement the filter replacement indicator on the control panel will turn red and the LCD display will read ‘FILT’. Please contact your local Radic8 distributor to purchase replacement HEPA and carbon filters. Changing the back filters 1.
  • Page 30 Cleaning the pre-filter The pre-filters in the back and bottom filter trays can be cleaned and reused. Radic8 recommends cleaning the pre-filters regularly for optimal performance, depending on the environment in which the device operates.
  • Page 31: Replacing The Reactor Chamber

    The Reactor Chamber must be replaced after 8,000 hours of use by a Radic8-approved technician only. Please contact your local Radic8 distributor or a Radic8-approved technician to have the Reactor Chamber replaced. Radic8 will provide the necessary servicing information and guidance as requested by the approved technician.
  • Page 32: Cleaning The Device

    If using a cleaning product, spray the product directly onto the cloth before wiping the device. Radic8 recommends using an 85% alcohol-based sanitizer for cleaning the body of the device. The device and its internals must not be exposed to excess moisture. Ensure the device is completely dry before being powered back on.
  • Page 33: Troubleshooting

    Radic8 VK Max - 1_en 7.5. Troubleshooting Problem Solution The device will not • Ensure the power cable is firmly seated in the device AC input and the wall switch on socket. • Ensure that the Timer function has not been activated.
  • Page 34: Error Messages

    VK Max - 1_en 7.5.1. Error Messages In the event of any of the below error messages, turn off the device, switch off the power at the wall socket, and contact your local Radic8 distributor for assistance. LCD display Text Description Er –...
  • Page 35: Specifications

    Radic8 VK Max - 1_en 8. Specifications Specifications and design of the VK Max are subject to change without notice. Operating Specifications Firmware Version: v0.3 Fuse: 5A Ensure correct mains voltage before use. 110–120V Device Voltage: AC 110–120V, 50–60 Hz Current: 5.6A...
  • Page 36 Radic8 VK Max - 1_en Noise (dBA): Up to 61 Typical Power: 375W ** IAQ Sensor: Particulate matter (PM) and volatile organic compounds (VOC) *** Reactor Chamber lifespan: 8,000 Hours HEPA filter lifespan: 6 months (approx. 4,000 hours) **** Carbon filter lifespan: 6 months (approx.
  • Page 37: Support

    Radic8 VK Max - 1_en 9. Support For hardware support, please contact your local Radic8 distributor or a Radic8-approved technician. Radic8 PTE Ltd 9 Raffles Place 27 – 00 Republic Plaza Singapore, 048619 info@radic8.com The model and serial number can be found on the label on the device.