Radic8 VK Air Manual
Hide thumbs Also See for VK Air:

Advertisement

Quick Links

Advertisement

Table of Contents
loading

Summary of Contents for Radic8 VK Air

  • Page 2: Table Of Contents

    4.4. Remote Control ..........................13 5. Installation ............................14 6. Operation .............................. 18 7. Maintenance............................22 7.1. VK Air Filters ..........................23 7.2. Changing the filters ........................25 7.3. Replacing the Reactor Chamber....................31 7.4. Cleaning the Device ........................32 7.5.
  • Page 3: Vk Air

    Radic8 VK Air - 1_en 1. VK Air User Manual Version 1.0 Document Number VKA-2-10.3 Copyright © 2022 Radic8 Page 1 of 37...
  • Page 4: Safety And Regulation

    VK Air - 1_en 2. Safety and Regulation Radic8 will not be responsible for any injury or loss resulting from the user’s failure to operate this device in accordance with its user manual, as updated from time to time, available on www.radic8.com...
  • Page 5: Safety Information

    • Do not immerse any part of the device in liquid or allow liquid or spray aerosols to enter the device. • In the event of smoke, unusual odors, or strange noises, switch off the device immediately and disconnect from power. Contact your local Radic8 distributor for support. Copyright © 2022 Radic8...
  • Page 6 Radic8 VK Air - 1_en • Dispose of device in accordance with local regulations. • Use biocides safely and sustainably. It is illegal to use this product in a manner other than prescribed on this label. • EU ONLY: This appliance can be used by children aged 8 years and over, as well as persons with...
  • Page 7: Regulatory Information

    VK Air - 1_en 2.2. Regulatory Information Use Environment The VK Air should be used indoors and must not be placed outdoors or anywhere that it will be exposed to water, rain, or the elements. User Proficiency The VK Air does not require any specific skills to operate. Follow the simple instructions when required to replace the filters and contact a Radic8-approved Distributor when the Reactor Chamber requires replacing.
  • Page 8 Radic8 VK Air - 1_en Ingress Protection or International (or Internal) Protection. IP20 indicates protection of this device against intrusion of solid objects larger than 12mm (accidental finger contact). Transport and Storage Symbols Indicates correct upright position of the transport package.
  • Page 9 Radic8 VK Air - 1_en FCC Notice This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 10: Warranty

    • Only Radic8 parts must be used when replacing consumables, maintaining and/or repairing this product, and failure to do so will exclude any warranty claim. • Only a Radic8-approved technician may perform any required repairs, and failure to do so will exclude any warranty claim.
  • Page 11: Product Overview

    Radic8 VK Air - 1_en 4. Product Overview The VK Air is a versatile and compact device that can be wall mounted or placed on a countertop for targeted indoor air decontamination. Copyright © 2022 Radic8 Page 9 of 37...
  • Page 12: Package Contents

    Radic8 VK Air - 1_en 4.1. Package Contents VK Air User manual IEC power cable Remote control (plug type based on region) (batteries not included) Copyright © 2022 Radic8 Page 10 of 37...
  • Page 13: Vk Air

    Radic8 VK Air - 1_en 4.2. VK Air Control panel Displays device information and provides input Filter tray Houses pre-filter and HEPA filter Side filter covers Secures the carbon filters Indoor Air Quality (IAQ) sensor Detects VOC and PM levels in...
  • Page 14: Control Panel

    Radic8 VK Air - 1_en 4.3. Control Panel IR sensor Accepts input from the included remote control LCD display Displays operational and device information Power button Switches the device on or off Up button Increases fan speed Down button Decreases fan speed...
  • Page 15: Remote Control

    Radic8 VK Air - 1_en 4.4. Remote Control Power button Switches the device on or off Mode button Displays and cycles through device information on the LCD display Up button Increases the fan speed Down button Decreases the fan speed...
  • Page 16: Installation

    Place device upright on a flat surface. 2. Installation Option 2: Wall mounted The VK Air can be wall mounted for targeted air delivery. The device should only be mounted by a qualified technician or contractor. Copyright © 2022 Radic8...
  • Page 17 Radic8 VK Air - 1_en • Only mount the device to solid concrete, brick, or wooden walls. The wall should be at least 50mm (2”) thick. • Mark an area where the device can be hung such that there is at least 300mm (11.8”) between the top of the device and the ceiling.
  • Page 18 Radic8 VK Air - 1_en 5. Insert power plug into wall socket. Ensure correct mains voltage. 6. The device will automatically power on in Auto mode. Copyright © 2022 Radic8 Page 16 of 37...
  • Page 19 Radic8 VK Air - 1_en Copyright © 2022 Radic8 Page 17 of 37...
  • Page 20: Operation

    6. Operation Turn the device on or off During installation, the VK Air will power on automatically. Turn the device off or back on again by pressing the power button ( ) on the control panel or on the remote control.
  • Page 21 Auto mode is indicated by ‘AUTO’ shown on the LCD display. In Auto mode, the VK Air detects the quality of the air with a built-in indoor air quality (IAQ) sensor that monitors levels of volatile organic compounds (VOCs) and particulate matter (PM): When increased levels of VOCs are detected, the LCD display will show ‘VOC’.
  • Page 22 To unlock the buttons, hold the Power button on the control panel for another five seconds. Set the timer The VK Air has a timer that can be set for three, six, or nine hours, after which time the device will power off.
  • Page 23 Radic8 VK Air - 1_en Deactivate the backlight Press the Lamp button ( ) on the remote control or the Mode button ( ) on the control panel once to turn the backlight on or off. Copyright © 2022 Radic8...
  • Page 24: Maintenance

    Before handling the device to perform maintenance, lightly mist the body with an 85% alcohol-based (or equivalent) sanitizer. Maintenance of your VK Air and replacement of consumables is essential to ensure the longevity of the device. Ensure the device is switched off and disconnected from the mains before conducting any maintenance.
  • Page 25: Vk Air Filters

    Radic8 VK Air - 1_en 7.1. VK Air Filters The VK Air contains two filter areas. The top filter tray contains the pre-filter and HEPA filter. The side filter covers contain the two carbon filters: Pre-filter Reusable. Clean regularly for efficient operation.
  • Page 26 Radic8 VK Air - 1_en Internal External Copyright © 2022 Radic8 Page 24 of 37...
  • Page 27: Changing The Filters

    7.2. Changing the filters When the carbon and HEPA filters are due to be replaced, the display will show ‘FILT’. Please contact your local Radic8 distributor to purchase replacement HEPA and carbon filters. Changing the HEPA filter Rotate out the handle at the top filter tray.
  • Page 28 Radic8 VK Air - 1_en Slide out the pre-filter and clean it with a damp dust cloth. Ensure the pre-filter is completely dry and reinsert it into the filter tray, facing the front of the device. Copyright © 2022 Radic8...
  • Page 29 Radic8 VK Air - 1_en Insert a new HEPA filter into the filter tray, towards the internal side of the tray. Ensure the arrow on the HEPA filter label points towards the inside of the device. Gently slide the filter tray back into the device and rotate the handle closed.
  • Page 30 Radic8 VK Air - 1_en Changing the carbon filters There is a carbon filter on each side of the device. For each side: 1. Remove the screw from the side filter cover and remove the cover: 2. Remove the used carbon filter and safely dispose of Copyright ©...
  • Page 31 Radic8 VK Air - 1_en 3. Insert the new carbon filter: 4. Replace the side filter cover and secure with the screw: Copyright © 2022 Radic8 Page 29 of 37...
  • Page 32 ) for five seconds to reset the filter timer. Cleaning the pre-filter The pre-filter can be cleaned and reused. Radic8 recommends cleaning the pre-filter regularly for optimal performance, depending on the environment in which the device operates. Clean the pre-filter with a damp dust cloth, ensuring the filter is completely dry before returning to the top filter tray.
  • Page 33: Replacing The Reactor Chamber

    The Reactor Chamber must be replaced after 8,000 hours of use by a Radic8-approved technician only. Please contact your local Radic8 distributor or a Radic8-approved technician to have the Reactor Chamber replaced. Radic8 will provide the necessary servicing information and guidance as requested by the approved technician.
  • Page 34: Cleaning The Device

    If using a cleaning product, spray the product directly onto the cloth before wiping the device. Radic8 recommends using an 85% alcohol-based sanitizer for cleaning the body of the device. The device and its internals must not be exposed to excess moisture. Ensure the device is completely dry before being powered back on.
  • Page 35: Troubleshooting

    Radic8 VK Air - 1_en 7.5. Troubleshooting Problem Solution The device will not • Ensure the power cable is firmly seated in the device AC input and the wall switch on socket. • Ensure that the Timer function has not been activated.
  • Page 36: Error Messages

    VK Air - 1_en 7.5.1. Error Messages In the event of any of the below error messages, turn off the device, switch off the power at the wall socket, and contact your local Radic8 distributor for assistance. LCD display Text Description Er –...
  • Page 37: Specifications

    Radic8 VK Air - 1_en 8. Specifications Specifications and design of the VK Air are subject to change without notice. Operating Specifications Firmware Version: v0.3 Fuse: 5A Ensure correct mains voltage before use. 110–120V Device Voltage: AC 110–120V, 50–60 Hz Current: 1.8A...
  • Page 38 Radic8 VK Air - 1_en Noise (dBA): 21–65 ** Typical Power: 140W *** IAQ Sensor: Particulate matter (PM) and volatile organic compounds (VOC) **** Reactor Chamber lifespan: 8,000 Hours HEPA filter lifespan: 6 months (approx. 4,000 hours) ***** Carbon filter lifespan: 6 months (approx.
  • Page 39: Support

    Radic8 VK Air - 1_en 9. Support For hardware support, please contact your local Radic8 distributor or a Radic8-approved technician. Radic8 PTE Ltd 9 Raffles Place 27 – 00 Republic Plaza Singapore, 048619 info@radic8.com The model and serial number can be found on the label on the device.

Table of Contents