Radic8 Viruskiller VK 102 User Manual And Instructions

Air steriliser

Advertisement

VK 102 / VK 103
AIR STERILISER
USER GUIDE AND INSTRUCTIONS

Advertisement

Table of Contents
loading

Summary of Contents for Radic8 Viruskiller VK 102

  • Page 1 VK 102 / VK 103 AIR STERILISER USER GUIDE AND INSTRUCTIONS...
  • Page 3: Important Safety Instructions

    Dear Customer Thank you for purchasing the VK 102 or VK 103 Air Steriliser, this is “clean air technology” at its best. This product is packed with power and technology to provide fast and efficient clean air. We hope that you enjoy using your new unit! READ ALL INSTRUCTIONS BEFORE USING YOUR UNIT When using your VK 102 or VK 103, basic safety precautions should be observed, including the following:...
  • Page 4: Table Of Contents

    USER GUIDE AND INSTRUCTIONS SUMMARY IMPORTANT SAFETY INSTRUCTIONS ..............3 SYMBOLS USED IN THIS MANUAL ..............4 INSTALLATION SAFETY ..................5 KEY PARTS AND COMPONENTS ................7 THE UNIT ....................7 DISPLAY MONITORING ................8 REMOTE CONTROL ................9 CLEANING AND MAINTENANCE ................10 CLEANING THE PRE- FILTER ..............
  • Page 5: Installation Safety

    INSTALLATION SAFETY Should the unit emit smoke, No form of water or liquid Do not place any heavy unusual odors or make any should enter the unit. Should objects on the power cord as this may cause a fire and/or strange noises, immediately this occur, immediately switch switch off the unit unplug it.
  • Page 6 Do not alter or modify the plug Use the proper power cable Keep the product away from inflammable gases, liquids, or or cord of this unit as it could and outlet, do not over-load cause a fire or an electric the outlets with several cords other combustible substances, shock.
  • Page 7: Key Parts And Components

    KEY PARTS AND COMPONENTS THE UNIT Four Way Air Outlet Display and monitoring Reactor Cell Sirocco Fan Carbon Filter HEPA Filter Pre Filter Four Way Air Inlet The VK 103 has an extra “back filter tray”, which allows it to integrated into a positive pressure system.
  • Page 8: Display Monitoring

    DISPLAY AND MONITORING Display Remote control TIMER sensor LED ON/OFF Reactor Replacement Alarm UVC ON/OFF Filter Replacement Fan speed UP Alarm Fan speed DOWN VOC’ s Static Display Dust Static Display (LED) Power button ON/OFF Name Function Display and Changes the information displayed on the LED in the following order: UV Monitoring Lamp Time, Current Temp, Fan Speed.
  • Page 9: Remote Control

    REMOTE CONTROL 5) LED Lamp On/Off 1) Power On/Off 3) Mode 2) Fan Speed 4) Timer Name Function Power ON/OFF To switch the unit ON/Off. You will hear a beep sound. Increase the fan speed. Fan speeds: FAN 1 (Quiet), FAN 2 (Normal), Fan Speed FAN 3 (High Speed).
  • Page 10: Cleaning And Maintenance

    CLEANING AND MAINTENANCE CLEANING THE PRE-FILTER VK 102 The plastic pre-filter is reusable. To clean it, follow this procedure: 1. Pull out the filter case ①. 2. Remove pre-filter ② from filter case ① and separate from carbon filter ③ and HEPA filter ④ 3.
  • Page 11: Replacing The Reactor Chamber

    Replacing the Reactor Cell In order for the VK 102 and VK 103 to remain functional, the reactor chamber must be replaced every 8000 hours. Your unit will indicate that a change is required by displaying a “-0001” code on the LED Display .
  • Page 12: Error Messages

    Cleaning the Air Quality Sensor (IAQ Sensor) Cleaning the Indoor Air Quality (IAQ) Sensor The IAQ sensor is a very delicate instrument that uses light scattering to detect pollution. It therefore needs a clean lens to work effectively. Regular maintenance (every 6 months) should be carried out to keep the lens clean.
  • Page 13: Troubleshooting

    TROUBLESHOOTING Before you call for service, review this list. It may save you time and expense. This list includes co- mmon occurrences that are not the result of defect in workmanship or materials. Problem Possible cause Solution The product The plug is not properly insert- Plug the device into a working grounded will not turn on ed in the grounded outlet.
  • Page 14: Customer Services

    CUSTOMER SERVICES In this manual, you will find a card containing details of your limited warranty. Please contact your distributor if you encounter issues with your unit or to procure replacement filters or reactor cham- ber when these reach their end of life. Damage or malfunction caused by negligence, abuse, unauthorized repairs or use not in accordance with the User Guide will not be covered.
  • Page 16 World Leading Air Sterilization Equipment Sales & Design: First Floor, Columbia Mill, Bedford Street, Bolton, BL1 4BA Tel : +44 (0) 1204 238823, E-mail: info@radic8.com, Manufacturer: INBair Korea LTD 3~4F, 72, Jomaru-ro 411 Beon-gil, Bucheon-si, Gyeonggi-do, South Korea E-mail: inbair01@naver.com, www.inbair.com...

This manual is also suitable for:

Viruskiller vk 103Vk 102Vk 103

Table of Contents