Download Print this page

Radic8 Viruskiller VK-Blue User's Manual & Instructions

Hide thumbs Also See for Viruskiller VK-Blue:

Advertisement

Quick Links

World Leading Air Sterilization and
Purification Equipment
VK - Blue
USER GUIDE & INSTRUCTIONS

Advertisement

loading

Summary of Contents for Radic8 Viruskiller VK-Blue

  • Page 1 World Leading Air Sterilization and Purification Equipment VK - Blue USER GUIDE & INSTRUCTIONS...
  • Page 2: Table Of Contents

    Table of Contents Safety Instructions ······················································· 1 Operation Instructions ·················································· 4 Key Parts and Components ··········································· 5 VirusKiller Functions ···················································· 6 Cleaning and Maintenance ·········································· 15 Error Messages ························································· 18 Troubleshooting ························································ 19 Customer Service ······················································ 21 Specifications ··························································· 22 Limited Warranty Card Important Safety Instructions The following instructions are provided to ensure your safety...
  • Page 3 Warning – This symbol indicates important safety instructions that must be followed to avoid injury. Caution – This symbol is to bring important information to your attention to avoid the risk of injury or damage to the unit. Prohibited – This symbol indicates a forbidden action. Adhere to these to reduce the risk of injury or damage to the unit.
  • Page 4 Operation Safety Keep the product away from flammable gases and • liquids, candles and open flames. Do not install near any heat sources • such as radiators, stoves, or other apparatus that produce heat. Do not attempt to repair or replace •...
  • Page 5: Operation Instructions

    Operation Instructions • Switch off while cleaning the room After cleaning, it is important to properly ventilate the room before using VirusKiller again. • Switch off while cooking Oils released while cooking may reduce the lifespan of the sterilizing module. After cooking, the room should be ventilated to remove oils.
  • Page 6: Key Parts And Components

    Caution • The appliance is not to be used by children or persons with reduced physical, sensory or mental capabilities. This appliance is not a toy. Children should be supervised at all times. • Never look directly at a burning ultra-violet light – this may permanently damage your eyes.
  • Page 7 Key Parts and Components Screw or Screw on anchor bolts Screw or Screw on anchor bolts 1. Air Inflow 2. Santized and Purified Air Outflow 3. Fan 4. Dual Reactor Module (Left and Right) 5. 8 x UVC Lamps and Multiple Nano Tube Filters 6.
  • Page 8: Viruskiller Functions

    Control Panel and Display Display and Indicator Fan speed Mode(Mood lamp) Power On/Off Remote Control Power On/Off Mood lamp On/Off Mood Fan speed Timer VirusKiller Functions Automatic Operation Mode When the unit is switched on, either by the power button on the body or the Power on/off button on the remote control, the product is in automatic mode.
  • Page 9 • Blue LED – Air quality is GOOD • Yellow LED – Air quality is NORMAL • Red LED – Air quality is POOR Note - When the unit is switched on the Indoor Air Quality (IAQ) sensor takes 2 minutes to calibrate. ②...
  • Page 10 ② • Fan speed increases when the UP button is pressed. FAN 1 Quiet Mode FAN 2 Normal Mode FAN 3 High Speed Mode • Reducing the Fan Speed ① To reduce Fan Speed ① Press DOWN button of main body. ▼...
  • Page 11 Operating the LED Lamp ② ① Turn on /off Mood lamp Keep pressing LAMP button of ① main body for few seconds. Press LAMP button of remote ② controller. Setting the Timer ① 1. Press TIMER button on the remote controller. 2.
  • Page 12 Mode Indicator ① State indication mode ① Press MODE button of main body briefly. ② Press MODE button of remote controller. ② Repeatedly pressing the MODE button on either the unit or the remote control changes the display in the following order: 0001 Operation time (in hours) of Sterilizing Module...
  • Page 13 To Switch the Unit Off ① Stop operation of the product ① Press POWER off swich of main body. ② Press POWER off swich of remote controller. ② To switch the unit off, press the POWER button on the unit or on the remote control.
  • Page 14: Cleaning And Maintenance

    Cleaning and Maintenance Cleaning the Pre-Filter The plastic pre-filter is reusable. To clean it follow this procedure: 1. Open front cover ①. 2. Remove pre-filter case from unit ② and separate from HEPA filter ③. 3. Clean the pre-filter with plain water. 4.
  • Page 15 Replacing the HEPA Filter ④ When the display shows ‘FILT’ at 2 minute intervals, it is time to replace the HEPA filter (2000 hours). After replacing the HEPA filter ③, press and hold the UP switch ④ for at least 14 seconds to reset the HEPA timer to zero.
  • Page 16 Cleaning the Indoor Air Quality (IAQ) Sensor The IAQ sensor is a very delicate instrument that uses light scattering to detect pollution. It therefore needs a clean lens to work effectively. Regular maintenance (every 6 months) should be carried out to keep the lens clean. Important - Only use pure water and allow to dry completely before replacing.
  • Page 17: Error Messages

    Error Messages When to Replace the Sterilizing Module The lifespan of the Sterilizing Module is 8000 hours. When the unit has been operated for 8000 hours, the operation time (displayed by pressing MODE) will be a minus figure, as shown below. Sterilizing Module should...
  • Page 18: Troubleshooting

    Troubleshooting Before you call for service, review this list. It may save you time and expense. This list includes common occurrences that are not the result of defect in workmanship or materials. • Problem : Product will not turn on. Possible causes Is power cord correctly connected to outlet? Solutions...
  • Page 19 Possible Causes Check the room size compared to the product specifications. Solutions Select the appropriate model of VirusKiller to suit the space to be covered. Possible Causes Check if airflow is restricted? Solutions Make sure there is sufficient clearance around the product and that the air inlet and outlet are not blocked by furniture, curtains, etc.
  • Page 20: Customer Service

    Customer Services In this manual, you will find a card containing details of your limited warranty and contact details for your local customer services center, to whom all enquiries and warranty claims should be directed. All warranties are rendered void and the cost of repair will be payable by the user in the case of: 1.
  • Page 21: Specifications

    Specifications The company reserves the right to make changes to the exterior, design or specifications of the product without prior notice. Air purifier Description VIRUSKILLER Brand VK-blue Model No Check back of unit Elec. Power 95 watt Elec. Consumption 7.5 Kg Net Weight 10.1 Kg Gross Weight...
  • Page 22 Sales & Design: Radic8 Ltd Man & Scythe Building 6 - 8 Churchgate Bolton, BL1 1HL Tel: +44 (0)1204 238823, E-mail: info@radic8.com, www.radic8.com Manufacturer: INBair Co., Ltd 3F, 15, Beotkkot-ro 12-gil,Geumcheon-gu, Seoul, Korea Tel: +82-31-811-1000, E-mail: inbair01@naver.com, www.inbair.com Made in Korea, Designed in England...