Philips SCOPEMETER PM93 Service Manual page 142

Table of Contents

Advertisement

CORRECTIVE MAINTENANCE
7 - 13
Comp Name (pin)
Scope
Freq.
Data
Description
Circ IIC
Per.
H/UA
t __
+4V
19
IACH2
0
H
I Analog channel 2
- - - - - - - - - - -
- - - - 0
l _____
+4V
20
IACH6
0
H
I Analog channel 6
- - - - - - - - - - - - - - -
- - - - --0
21
IACH7
0
A
I Analog channel 7
22
NSS
0
L
Noltage supply
ground (0)
23
IACH5
0
L
I Analog channel 5
24
HLDOFN/ACH4
__ l ____ J
_____ L _____ L_
H
I A Hold off not I Analog
channel 4
25
IANGND
0
L
IAnalog ground (AID
convertor)
+5V
26
NREF
0
H
Nreference (AID convertor)
- - - - - - - - - - - - - - - - - - - -
- - - - --0
27
NSS
0
L
IClock Detect Enable
28
ACQRDY IEXTINT
_J1IlJULfJIL _____
",,50 Hz
A
Acquisition ready/External
interrupt
l ______
+5V
29
NCC
0
H
IMain supply (+5V)
- - - - - - - - - - - - - - - - - - - --0
l __________
+5V
30
/lPRESET/RESET
0
H
/lP reset Ireset
- - - - - - - - - - - -
- - --0
t _____
+5V
31
IRXD
0
H
IReceive data/port 2
- - - - - - - - - - - - - - - -
- - - --0
t ______
+5V
32
/TXD
0
H
/Transmit data/port 2
- - - - - - - - - - - - - - - - -
- --0
33
NSS
0
L
Noltage supply
ground (0)
34
COAT IP1.0
_rrnnIlI ____
",,20/ls
A
Cbus DATA IPort 1.0;
repeated each 30-60 ms
35
DTAEb/P1.1
I
I
I
30-60 ms
L
DATA enable IPort 1.1
36
FRONTCLOCKlP1.2
_lJlIl[lJJJ __
60 kHz
A
Front clock IPort 1 .2;
repeated each 30-60 ms
37
CCLK IP1.3
llilllilillL _______
100 kHz
A
Cbus clock IPort 1.3;
repeated each 30-60 ms
38
PSO IP1.4
_ JllilllIlllliIl __
40 Hz
A
page select 0 IPort 1.4
l
+5V
39
FRONTDATA1/HS1.0
0
H
Frontdata 1 IHigh speed input
- - - - - - - - - - - - - - - - - - - - - -
- --0
1.0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scopemeter pm95Scopemeter pm97

Table of Contents