Charger Display
Mode
Self-inspection
completed
Self-inspection failed
Normal Charging
Fully Charged
Hot/Cold Battery
Error
NOTICE: Charger may become warm with several continuous charge cycles. This is part of
the normal operation of the charge. Charge in a well-ventilated area.
Charger Error
If the charger self-inspection fails to react when the charger is plugged in, the causes include
no power to the charger, bad contacts, or a charger failure. Check to see if the charger self-
inspection can be activated when the charger is plugged in again or plugged into a different
outlet. If it still fails, have the charger serviced by an Authorized SKIL Service Station.
Battery Pack Error
If the charger detects a problem, the red Error Indicator will begin flashing. Remove and
reinsert the battery pack in the charger. If the Error Indicator still flashes, try charging a
different battery pack.
a. If a different battery pack charges normally, have the first failed battery pack serviced by an
Authorized SKIL Service Station.
b. If a different battery pack also fails to charge, the problem may be with the charger. Have
the charger serviced by an Authorized SKIL Service Station.
Charging Indicator
(green)
Flash once
Either or both are off
Flashing
Steady
Off
Off
Error Indicators
Fuel Gauge on
(red)
Battery Pack
Flash once
according to
Off
capacity level.
Off
Steady
Flashing or Off
All the four
Off
indicators flash once
At least one will
have no reaction
Off
when the charger is
plugged in.
Flashing
The charger will
automatically start
the current
charging the battery
pack, if the battery
pack temperature is
within the charging
Off
temperature range.
Remove the battery
Off
from the charger.
Off
Charging Error.
Note
13