Mitsubishi Electric LE-40MT Series Handbook page 14

Tension controller
Table of Contents

Advertisement

Item name
LE-40MTA, B(-E)
Function
Terminal
Tension
Input
GRL
detector
WHL
GRR
WHR
SG
Analog
Input
AI1
AI2
AI3
AIC
Output
TMO
AOC
Contact
Input
MC1
MC2
MC3
MC4
MC5
MC6
MCC
Output
ZT
ZT
Terminal specifications
Since the terminal type changes from a screw type terminal to a spring clamp type terminal, stranded wires and bar type crimp
terminals are used for wiring. Therefore, when using a round terminal and Y terminal, terminal processing of the wiring is
necessary.
2 TRANSITION FROM LE-40MTA, B(-E) TO LE7-40GU-L
12
2.2 Comparison of I/O Terminal Blocks
Specifications
Left
Tension detector input
Connect the lead wires GR=green (blue) and
WH=white.
Right
Use the parameter to specify the number of
detectors to be used: one or two.
The connection varies depending on the
compression/tensile load. When one detector is
used, it is necessary to make a short circuit
between GRL and WHL.
For shield connection
External tension setting: 0 to full scale tension at 0
to 5 V DC
Internal resistance: 100 k
Recommended potentiometer (control): 5 V 10 k
Selection from reel diameter, stall, new-reel taper
ratio setting, and external tension
Recommended potentiometer (control) 5 V 10 k
Analog input common
Output for tension monitor
Filter adjustable by parameter
0 to 5 V DC
Load resistance: 1 k or more
Analog output common
Operation/stop: ON=automatic operation,
OFF=stop
Reel change signal: OFF=A reel, ON=B reel
Gain 1 operation: Gain 1 enabled during ON
Stall memory reset: About 0.5 second one-shot
input
Assigned by parameter settings and used.
• Gain 2: Gain 2 enabled during ON
• Inching: Output lower limit restriction, stall
memory update stop
• OUT remote: Control output ON during ON
• Cut torque: During ON, output lower limit
restriction, cutter
Contact input common
• Zero tension detection output: Set value 0 to
1999 N (199.910 N)
• Output ON at tension below the set value:
Always OFF when the set value is 0 (however,
the output is ON regardless of the set value and
tension when the watchdog timer is operating).
• Relay output (250 V AC 0.5 A or 30 V DC 0.5 A)
LE7-40GU-L
Terminal
Specifications
GRL
Left
Tension detector input
• Input range switchable
WHL
(1) -150 to +150 mV DC (LX tension detector)
GRR
Right
resolution: Approx. 7.90 V
(2) -15 to -15 mV DC (strain gauge) resolution:
WHR
Approx. 0.790 V
When only the detector on one side is used, it is
necessary to make a short circuit between GR and
WH on the other side.
The compression/tensile load is determined
automatically.
SLD
For shield connection
AI1
Selection from tension setting, stall, taper ratio,
new-reel preset, manual, tension input, and reel
• Input range switchable
(1) 0 to 5 V DC resolution: Approx. 193 V
(2) 0 to 10 V DC resolution: Approx. 193 V
AI2
• Input resistance 38 k
AI3
AIC
Analog input common
AO1
Selection from tension monitor, reel diameter
monitor, tension setting monitor, A-reel shaft
AO2
rotation speed output, and B-reel shaft rotation
speed output selection
• Output range switchable
(1) 0 to 5 V DC resolution: Approx. 358 V
(2) 0 to 10 V DC resolution: Approx. 358 V
• Load resistance: 1 k or more
AOC
Analog output common
DI1
Selection from operation/stop, control output OFF/
ON, stall memory, inching ON/OFF, constant
tension ON/OFF, gain 1 ON/OFF, gain 2 ON/OFF,
DI2
auto/manual, reel change ON/OFF, cut torque ON/
DI3
OFF, and alarm reset ON/OFF
• Input signal voltage 24 to 28.8 V DC
DI4
• ON current about 5 mA
• Sink/source input
DI5
DI6
0V
In sink input mode, 0 V becomes contact input
common.
S/S
In sink input mode, this terminal connects to 24 V.
DO1
Selection from no function, tension lower limit
detection, tension upper limit detection, tension out
DO2
of range detection, and alarm occurrence detection
• Open collector output (30 V DC, 0.1 A or less)
DOC