MAKSIWA CBC.P PREMILLING UNIT
2.4.2 Tilt adjustment
Adjust the unit angle, losing the motor fixing bolts and moving the unit with stop position
bolts.
3 MAINTENANCE
Before starting the Maintenance, turn off the machine (disconnect completely electrically) and
disconnect compressed air.
Only trained personnel can perform these operations.
3.1 General maintenance
•
Daily remove (vacuum) dust that may be near the unit.
•
Grease the linear guides. Perform this operation every 3 months.
•
Check manually daily, without pneumatic pressure, that the motor moves
correctly, without any obstruction.
Motor fixing
bolts
Stop position
bolts