5-2 PLL ADJUSTMENT
1ST/2ND VCO LOCK VOLTAGE must be verified on the normal mode.
MEASUREMENT
წყება.
ADJUSTMENT
ADJUSTMENT CONDITION
LOCATION
UNIT
|ADJUST
* Displayed frequency :
Connect
the
ОС|1.5У-2.5У
145.000 MHz
voltmeter to the L68.
* Transmitting
* Displayed frequency :
less than 7.2 V
449.980 MHz
* Receiving
* Displayed frequency :
19V-2.9V
493.300 MHz
* Receiving
* Displayed frequency :
less than 11.0 V
282.900 MHz
* Receiving
* Displayed frequency :
1.8 У + 2.8 У
283.000 MHz
* Receiving
* Displayed frequency :
less than 9.2 V
493.295 MHz
* Receiving
* Displayed frequency :
voltmeter
to
Ше|0.2\
- 12V
430.000 MHz
* Receiving
* Displayed frequency :
less than 2.5 V
433.500 MHz
* Receiving
* Displayed frequency :
voltmeter
to
the
(tk ch)
145.600 MHz
check point QUAD.
* Connect an SSG to the antenna
connector and set as:
Level
: 1 ту" (-47dBm)
Deviation
:+ 3.5 kHz
Modulation
:1 kHz
* Receiving
*This output level of the standard signal generator (SSG) is indicated as SSG's open circuit.
L21
Detector output voltage adjustment
SEN
VHF and UHF sensitivity check point
L68
QUAD
T
/
lock
h
2nd VCO lock voltage check point