7.1.2) Topping up the oil in the hydraulic pump (Ref. to Fig. 19)
Periodically check the level of the oil in the hydraulic
pump. The oil should always be visible inside the
tank (03). If the level is low, top up with the specifi c
oil recommended:
– Unscrew the cap and add suffi cient oil to fi ll the
tank; do not exceed the oil level.
– After topping up, tightly screw the cap back on.
Always use clean recommended oil, see § 1.
Do not use old or recycled oil.
Do not use hydraulic brake fl uid.
7.1.3) Changing worklight bulbs
– Loosen the locking nut (Ref. to Fig. 20).
– Turn worklight upwards and remove the two
screws in the lens (Ref. to Fig. 21) using a screw-
driver.
– Remove the faulty bulb and replace with another
having the same specifi cations: 12V - 21W
– Replace lens and tighten the two screws.
– Reset worklight to original position and tighten
the nut.
The light bulb power circuit is protected by a
fuse against overcurrents and short-circuits.
In case of a fault:
– Remove the 4 screws from the lid of the termi-
nal box (14) using a screwdriver.
– Pull out fuse carrier and open it (Ref. to Fig. 22).
– Replace faulty fuse with a new one with the
same specifi cations: 6,3A - 250V.
– Push fuse carrier back, replace lid and tighten
4 screws.
14
fuse-carrier
FIG. 22
03
FIG. 19
locking
nut
FIG. 20
light bulb
12V - 21W
FIG. 21
24
9