Description Of The Pandrol Fastclip - Cembre PCM-2P/FC Operation And Maintenance Manual

Machine for pandrol “fastclip” fastening
Table of Contents

Advertisement

4.4) Description of the "Pandrol Fastclip"
The "FASTCLIPS" have three positions:
PARKING POSITION
All components are captive.
INSULATOR CHANGE POSITION :
The Fastclip is withdrawn to the rear detent so that the
side post insulator can be removed.
FIG. 6 – FASTCLIP
(Ref. to Fig. 6)
Toe insulator
INSTALLED POSITION:
The Fastclip holds the rail.
12
TROUBLESHOOTING
When the starting cable is pulled, the engine fails to start:
Is the Stop/Emergency button (06) released? (see § 4.3).
Is there enough oil in the combustion engine?
– The engine features an oil alert system to prevent damage caused by too little
oil. Before the level drops below safe limits, the alarm system automatically
stops the engine.
Refer to the "HONDA owner's manual" for the type of recommended oil and topping up.
THE HYDRAULIC OIL SUPPLIED WITH THE MACHINE IS INTENDED ONLY FOR
USE IN THE HYDRAULIC PUMP AND IS MUST NOT BE USED IN THE ENGINE.
Is the fuel stopcock open?
Is there fuel in the tank?
Is fuel reaching the carburettor?
– To check, loosen the carburettor drainage screw with fuel cock open and refer to the
"HONDA owner's manual" .
Is the spark plug producing a spark?
– Remove the plug cap, clean around of the plug and remove the plug using the span-
ner provided.
– Fit the plug back in the cap.
– Move button (06) to ON.
– After earthing the side electrode, pull the starting cable and check to see whether the
plug produces a spark.
If the engine still fails to start, contact CEMBRE (see § 9).
21

Advertisement

Table of Contents