Cembre B1350-C-KV Operation And Maintenance Manual page 7

Battery operated hydraulic crimping tool
Hide thumbs Also See for B1350-C-KV:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 5
To replace the battery, remove it by pressing the release button (7) (Ref. to Fig. 1), then insert the
new battery, sliding it into the guides until it locks.
The display shows the operational parameters of the tool; to customise them proceed as described
in § 2.7.
Select the appropriate die set for the connector.
Insert one die into the upper seat of the tool head (Ref. to Fig. 2) until it is locked by retaining pin
(13), to ease the die insertion keep release pin (12) depressed.
Insert one die into the seat on the ram until it is locked by retaining pin (15).
To ease this operation, operate the tool (see § 2.2) to advance the ram (11) 8-10 mm (0.3 - 0.4 in.)
and keep release pin (14) depressed.
Insert the conductor into the connector (Ref. to Fig. 3).
Position the connector between the dies and ensure the correct location of the crimp (Ref. to
Fig. 4).
NOTE
: when more compression is
required, proceed according to the
sequence and direction indicated
in the figure, uniformly spacing the
compressions.
2.2) Die advancement
Press operating button (4) (Ref. to Fig. 4) to activate the motor-pump and advance the lower die.
To halt the advancement, release operating button (4) and the motor will cut out.
Make sure the dies are exactly positioned on the desired crimp point otherwise re-open dies
following instructions as per § 2.4 and reposition the connector.
2.3) Compression
By keeping operating button (4) pressed, the motor continues to operate: the ram will gradually
move forward until the two dies touch.
The motor will stop automatically when the set pressure has been reached.
To perform proper compression, press and hold the operating button (4) until the motor
stops automatically.
7
terminal
2
1
2
1
connector
1
2

Advertisement

Table of Contents
loading

Table of Contents