4.4) ERRORS:
these appear during operation, combined with a beep and flashing LED Worklights,
to notify the operator of procedural or operational errors.
Message
Error description
The pressure release button (5) was
ERROR
pressed before the control parameters
were reached (Force/Pressure).
Interruption of the signal from the NTC
ERROR
NTC
temperature probe of the battery.
FAULT
ERROR
001
ERROR
Abnormal power consumption of the
ERROR
motor for more than 3 seconds.
001
002
The tool stops.
001
001
002
003
Output voltage of the pressure transmit-
001
002
ter is out of the pre-set range.
002
003
004
002
Failure to reach the set pressure within
003
003
30 seconds of continuous operation of
004
the machine.
003
004
Overcharging of the battery with protec-
004
tion tripping.
004
The tool stops.
Errors are displayed for about 30 seconds before being reset, but will display repeatedly in
the event of permanent anomalies.
5. CONNECTION TO COMPUTER (Smartool thecnology)
The memory card integrated in the tool records operating data for transfer via the USB cable supplied.
To view and manage this data, go to www.cembre.com and register in the dedicated area, then
download the free CEMBRE software CEM_SWBT01.
Keeping the Firmware of the tool updated, via free of charge download from here, will optimise
the tool's performance.
Solution
Repeat the work cycle and wait for the motor
to stop automatically.
Replace the battery.
If the problem persists, please contact
CEMBRE.
Wait for the display to turn off (60 sec.) or
remove and re-insert the battery, then re-
start the tool.
If the error occurs frequently, contact CEMBRE.
Repeat the work cycle; if the error
occurs frequently, contact CEMBRE.
Repeat the work cycle; if the error occurs
frequently, contact CEMBRE.
Wait for the display to turn off (60 sec.) or
remove and re-insert the battery, then re-
start the tool.
If the error occurs frequently, contact CEMBRE.
12