The appliance can be used by children aged 8 or over and by people with reduced
physical, sensory or mental faculties, or who do not have the required experience
or knowledge, provided they are supervised or have received instructions on
using the appliance safely and understanding its intrinsic hazards. Children must
not play with the appliance. The cleaning and maintenance operations reserved to
the user must not be performed by unsupervised children.

1. SAFETY PRECAUTIONS

1.1. WARNINGS FOR INSTALLERS

-
The air conditioner may only be installed, plumbed in and wired by persons who meet the
technical and professional requirements to install and maintain such systems.
-
This air conditioner must be installed in accordance with national plant engineering
regulations. Pay particular attention to the aspects concerning safety and the proper
connection of electrical cables. Errors while connecting cables may lead to fires.
-
Connect the air conditioner to the mains or to a power socket with a suitable voltage and
frequency. A power supply with an incorrect voltage and frequency may result in damage to
the unit with a consequent fire risk. The voltage must be stable and without excessive
fluctuations.
-
Install the condensation drainage piping so as to ensure that the condensation is removed
correctly. Also adopt the most appropriate solutions to prevent heat loss and the resulting
formation of condensation. An incorrect piping configuration may lead to water leakage and
wet furniture and objects in the indoor environment.
-
The air conditioner must be earthed. Incomplete or poorly set-up earthing may cause electric
shocks. Do not connect the earthing cable to other pipes, water pipes, lightning rods or the
telephone earthing wire.
-
Install an omnipolar switch (with a minimum contact distance of at least 3 mm on all poles)
on the power supply circuit to prevent possible discharge to ground and short circuits.
-
The omnipolar switch and any socket must be installed in an easily accessible location.
-
Do not remove the power cable while the unit is running or with wet hands. Doing so risks
electric shocks and fires.
-
Use cables that are intact and whose cross-section is appropriate for the load for the power
supply.
-
Do not make joints on the power cable. Use a longer cable if necessary. Joints can cause
overheating or fire.
-
In the event that the power cable is damaged, it must be replaced. Use a type of cable
featured in the manual
-
Install a noise filter if the power supply emits too much
-
Do not leave any cables in direct contact with the refrigerant piping which could reach
excessive temperatures.
-
Do not leave any cables in direct contact with moving parts, such as fans. Make sure the
communication cables between the units are connected to the correct
-
Only replace fuses with ones identical to the original.
-
lf the filter is very dirty, this will significantly reduce the cooling capacity of the appliance.
-
Tighten the nut to the torque indicated in the device manual. Overtightening can lead to
leakage of refrigerant.
only.
noise.
3
terminals.

Advertisement