Hang the indoor unit on the support using the upper tabs. Make sure that the indoor unit is in
the
middle.
•
Position and push the indoor unit onto the mounting plate until the hooks attach firmly into the
guides and you hear them "click" into place.
INSTALLATION WITH SIDE CONNECTIONS
•
It is also possible to install the indoor units using the
existing side pre- shearing.
•
Please note that the wiring, the drainage, and the
refrigerant connections are fully
either side of the unit.
•
Even when installing with feedthrough
up all the connections to prevent condensation problems.
DRAINAGE PIPE
•
Bear in mind that water drainage takes place due to gravity.
•
Connect the drainage pipe to the thermally isolated plastic pipe from the right side of the indoor
unit (rear view).
•
Make sure the drainage pipe comes out from the indoor unit with a negative slope (downwards).
The highest point of the outlet connections must not exceed the position of the tank.
NOTE: The drainage pipe can be connected to either
connector 1 or 2. lf it is necessary to change the side of the
drainage pipe, remove the rubber cap on the connector and
secure it on the unused side
using a screwdriver.
suited for connection on
connections,
wrap
12
Connection pipe
Connection pipe
Drainage pipe
Wall
Mounting bracket
Connector 2
Screwdriver
Support
Piping
Electrical cable
Drainage pipe
Connector 1
Rubber
cap