Supermicro X13DEH User Manual page 62

Table of Contents

Advertisement

Super X13DEH User's Manual
Standby Power SMB (I²C)
A Standby Power (I
the system when it is in standby mode. Refer to the table below for Pin definitions.
Power Fail LED Indicators
Power Failure LED Indicators are located on Pin 15 and Pin 19 of JFP1. Refer to the table
below for pin definitions.
JFP1
1
2
FP_PWRBTN_N
1
2
FP_UID_RESET_SW_N
3
UID_LED
4
FAIL LED
LAN2_LED_N
5
6
LAN1_LED_N
HDRV_LED_N
7
8
FP_STBYLED_CPLD_N
FP_PWR_LED_N
9
10
P3V3_STBY
11
Ground
12
SMB_SEN_DAT
4
SMB_SEN_CLK
13
14
Ground
5
15
16
FP_LED_P
P5V_USB20_FRONT
P5V_USB20_FRONT
17
18
P5V_USB20_FRONT
6
19
20
Ground
FP_LED_N
19
20
J40
JCOM1
FAN10
FAN11
FAN12
JRK1
RAID KEY-1
BIOS
M. 2 MH-A
LICENSE
JUSB3
BIOS
JTPM1
PCH
CPLD Flash
JPFR2
CPLD2
Battery
JPCIE2B1 JPCIE2A1 JPCIE3A1 JPCIE3B1
+
X13DEH
BT1
JBT1
JPCIE1A1 JPCIE1B1
REV:1.01
CPU1
JPCIE5A1 JPCIE5B1
JPCIE6B1 JPCIE6A1 JPCIE7A1
JPCIE7B1
JNCSI1
FAN4
FAN5
C) connection, located on Pin 10 ~ Pin 14 of JFP1, provides power to
2
3.3V Standby PWR
Pin Definitions
Pin#
Definition
10
P3V3 Standby
11
Ground
12
I²C Data (SMB_SEN_DAT)
13
I²C Clock (SMB_SEN_CLK)
14
Ground
FP Power LED
Pin Definitions (JFP1)
Pin#
Definition
15
PWR Failure LED-Positive
19
PWR Failure LED-Negative
2
3
1
JFP1
JPDB1
JFP2
LED2 LED1
M. 2 MH-B
JPWR3
Power Supply Unit 2
Power Supply Unit 1
PSU2 PSU1
PWR_OUT
PWR_In
GND
+12V
JPCIE4B1
JPCIE4A1
CPU2
BAR CODE
JPCIE8A1 JPCIE8B1
CN4
JPCIE9B1
JPCIE9A1
1. JFP1 (Control Panel Header)
2. Pin 10: P3V3 Standby
3. Pin 12: I²C Data (SMB_SEN_DAT)
4. Pin 13: I²C Clock (SMB_SEN_CLK)
5. Pin 15: PWR Failure LED-Positive
6: Pin 19: PWR Failure LED-Negative