Dometic FreshJet FJX Installation Manual page 26

Roof air conditioner
Hide thumbs Also See for FreshJet FJX:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
EN   Dometic FJX
Cooling capacity based on ISO
5151:
Heating capacity based on ISO
5151:
AC Input voltage:
Rated current cooling:
Rated current heating:
Required fuse:
Operating temperature range:
Refrigerant:
Refrigerant quantity:
CO
equivalent:
2
Global warming potential
(GWP):
Protection class (roof top unit):
Noise level (highest fan setting)
Frequency
Maximum radio frequency
power
Suggested max. vehicle length
(with insulated walls):
Dimensions L x W x H:
Weight:
Inspection/certification:
24
FreshJet FJX7333IHP
2200 W
2000 W
220 V ... 240 V /
50 Hz ... 60 Hz
< 7.5 A
< 6.1 A
6 A
-2 °C ... 52 °C
R32
420 g
0.28 t
≤ 7 m
Fig. 
< 30 kg
FreshJet FJX7337IHP
3000 W
2500 W
220 V ... 240 V /
50 Hz ... 60 Hz
< 7.5 A
< 6.1 A
6 A
-2 °C ... 52 °C
R32
480 g
0.32 t
675
IPX4
< 70 dB(A)
2.4 GHz
19.14 dBm
≤ 7 m
Fig. 
< 35 kg
FreshJet FJX7457IHP
3500 W
3000 W
220 V ... 240 V /
50 Hz ... 60 Hz
< 7.5 A
< 6.1 A
6 A
-2 °C ... 52 °C
R32
650 g
0.44 t
> 8 m
Fig. 
< 40 kg

Advertisement