3. Press the START/PAUSE button. The Vent Blockage Test starts immediately. During the test, the number
indicator makes a circle in 6 clockwise steps. The test takes about 2 minutes. Do not open the door during the
test.
4. After 2 minutes, when the test is complete, the results is displayed and the dryer sounds a tone.
If status of the duct system is normal, "0" appears and the dryer sounds a completion tone.
If the duct system can not exhaust properly, "Cg" appears and the dryer sounds an alarm tone.
If there are any other problems, an information code appears in the display. For information about the code,
see Information codes section on page 38.
To stop or cancel the Vent Blockage Test, press the POWER button to turn off your dryer.
During the test, if "dc" appears in the display, make sure the door is closed. If "C1" is displayed, see if there
is laundry inside drum. If there is, stop the test and remove it. Then, start the test again.
The results remain on the display for about 5 minutes and then automatically turn off. You can turn the
result off immediately by pressing the POWER button.
During or after the test, the internal drum is hot. Use caution to prevent burns.
The Vent Blockage Test is used to check for problems to the current duct system when the dryer is
installed for the first time.
If the test result displays "Cg" (the duct system is blocked ), refer to the "Ducting requirements"
section on page 12 and the "Exhaust ducting guide" section below, and then take proper measures
to correct any problems.
If the test is suspended, it could result in incorrect results. Follow the proper procedures when testing
the dryer.
Even if the test result is normal ("0"), the duct system could be blocked slightly. Properly install all duct
work according to the installation instructions in this manual.

Exhaust ducting guide

Ducting

1. Make sure the dryer is installed properly so the air exhausts freely.
2. Use 4-inch rigid metal ducts. Tape all joints including the dryer connection.
Never use lint-trapping screws.
3. To facilitate the exhaust, keep the ducts as straight as possible.

Cleaning

Clean all old ducts before installing the dryer, and make sure the vent flap opens and closes freely. We recommend
that you clean the exhaust system annually or on a regular basis.
WARNING
To prevent fire, do not use plastic, thin-foil, or non-metal flexible ducts of any kind.
Do not use a poor exhaust system because it slows down the dryer's performance.
Do not use excessively long ducts that have multiple elbows.
Do not use crushed or clogged venting or ducts.