JOB list switching (P12)
Value Designation
0
Task-oriented
JOB list
1
Actual JOB list
2
Actual JOB list,
JOB changeover active
Creating user-defined JOB lists
A consecutive memory range where accessories such as the POWERCONTROL 2 torch can be
used to switch between JOBs will be created.
Set special parameter P12 to "2".
Set "Program or Up/Down function" changeover switch to "Up/Down" position.
Select an existing JOB which is closest to the required result.
Copy JOB to one or more target JOB numbers.
If any JOB parameters need to be changed, select the target JOBs in sequence and change the
parameters individually.
Set special parameter P13 to the lower limit and
Set special parameter P14 to the upper limit of the target JOBs.
Set "Program or Up/Down function" changeover switch to "Program" position.
JOBs can be changed over in the specified range using the accessory component.
Copying JOBs, "Copy to" function
The possible target range is between 129 - 169.
First configure special parameter P12 to P12 = 2 or P12 = 1!
099-005404-EW501
16.01.2017
Explanation
The JOB numbers are sorted by welding wires and shielding gases.
JOB numbers may be skipped during selection where relevant.
JOB numbers correspond to the actual memory cells. Each JOB can be
selected; no memory cells are skipped during selection.
As for the actual JOB list. JOB changeover is also possible with
accessory components, such as the PowerControl 2 torch.
5s
Design and function
Special parameters (advanced settings)
Figure 5-75
3s
91