Cable Connector Configurations
Aux Port Configuration Cable*, PN 57-57008x-N-3
Pin
1
No Connect
2
Output from Scanner
3
Input to Scanner
4
No Connect
5
Ground
6
No Connect
7
No Connect
8
No Connect
9
No Connect
RS232 LSO/AUX Cable
PN 57-57099x-3 or PN 57-57099x-3-12
Pin
1
Signal Ground
2
RS232 from Aux / Secondary Scanner
3
RS232 to Aux / Secondary Scanner
4
RTS from Aux / Secondary Scanner
5
CTS to Aux / Secondary Scanner
6
No Connect
7
No Connect
8
No Connect
9
+5VDC – Transformer / Direct
10
Shield Ground
* This configuration cable was designed to be used with the MS2421/MS2422/MS2431 auxiliary
connector only.
** All signals are referenced from the MS2421/MS2422/MS2431 scanner.
All signals are referenced from the auxiliary / secondary scanner.
Specifications are subject to change without notice.
54
Function**
Function
9-Pin D-Type Connector
10-Position Angled Modular Plug