Plumbing
This equipment to be installed with adequate backflow protection to comply with applicable federal, state,
and local codes.
§ 3/8" OD push-in water inlet - 3/8" OD tubing required
§ 3/4" MPT drain
§ 1/4" FPT condenser inlet (water-cooled condenser only)
§ 1/4" FPT condenser drain (water-cooled condenser only)
Notes:
§ Water shut-off recommended within 10 feet (3m).
§ Water supply must have particle filtration. Follett recommends the filter system that has integral scale inhibitors.
(Follett item# 00130286).
§ Follett does not recommend the use of water softeners or bowl scale inhibitors.
Flush drain plumbing
§ 3/4" MPT flush drain connection at the rear of the machine.
§ Drain must slope 1/4" inch per foot (6 mm per 30.4 cm).
§ Drain line should not be shared with any other piece of equipment.
§ Drain line cannot be reduced to a size smaller than 1 inch.
§ Drain should be piped without a vent.
silicone tubing
(6,4 mm per 0,3 m)
Chassis drain plumbing
§ Plug must be removed from John Guest fitting.
§ Route 3/8" drain tubing through knockout in back of docking station and insert fully into John Guest fitting
connection at the rear of the machine chassis. Route other end of 3/8" drain tubing to drain.
§ Drain must slope 1/4" inch per foot (6 mm per 30,4 cm).
4
3/4" barb x 3/4" FPT
2 ft. x 1" OD
1/4" per foot
1'
WARNING
3/4" MPT x 1" slip
1" PVC Drain
HCC1010A/W, HCD1010A/W, HCC1410A/W, HCD1410A/W
Minimum 8"
radius
2 ft. x 1" OD
silicone tubing
3/4" barb x 3/4" FPT
3/4" MPT x 1" slip
1" Stand pipe/Drain