Install the shower fittings, refer
to the Installation Guide packed
with the product.
Check for leaks on all connections
you have made.
Commissioning
Maximum Temperature Setting
Before using the shower, the maximum temperature must be checked to make sure
that it is at a safe level. It has been preset to a safe showering temperature under
ideal conditions at the factory, appropriate for most systems. However, site conditions
and personal preference may make it necessary to reset this temperature.
Note: Make sure that the hot water temperature is at least 55°C and that
there is sufficient supply.
Caution! Before testing the mixer, make sure that the hot and cold water
is flowing correctly by exercising the temperature handle from hot to cold.
1.
Turn the temperature handle anticlockwise until it stops and test that the
temperature of the water from the shower outlet is hot enough.
2.
If not, depress the override button and carefully rotate the handle further. If the
water temperature is still not hot enough complete the following procedure.
3.
Rotate the temperature selector handle back to the override position.
4.
Remove temperature handle by pressing the override button and pulling the
handle.
Note: The end
cap on the Assist
handles must be
removed before
pulling off.
Flow Regulator
Washer
A 6 l/min flow regulator can be fitted into the outlet.
Note: Orientate flow regulator as shown
above.
End Cap
13
Mixing
Valve
Shower Hose
Temperature
Handle
1320703-W2-B
Override
Button