Using The Remote Control; Remote Control Transmitter Functions; Setting Pilot To Ipi Versus Cpi Mode - Mendota FV44 DECOR Installation & Operating Instructions Manual

Fullview direct vent gas fireplace insert heater
Table of Contents

Advertisement

USING THE REMOTE CONTROL

BEFORE YOU BEGIN
Read this entire manual before you use your new fireplace insert (especially the section "Safety Precautions"). Failure to
follow the instructions may result in property damage, bodily injury, or even death.

Remote Control Transmitter Functions

NOTE: The Wall Receiver will "beep" once every time
a Remote Transmitter Key is pressed, signaling that
the command has been received.
Identify the four function buttons on the Remote
Transmitter:
1. ON/OFF KEY: This button turns the
system ON or OFF. When this but-
ton is pressed and the system is
OFF, the pilot light will stay ON if
the "Standing Pilot Switch" is in the ON position.
2. THERMOSTAT KEY: This button, when pressed after the ON/OFF KEY is pressed and the sys-
tem is ON, will allow the selection of three modes: Manual Operation, Normal Thermostat and
Smart Thermostat.
a. Manual Mode: In this mode, the room temperature is ignored and the fireplace can be turned ON indefinitely. The
room temperature rise has no effect on this mode. All other functions such as fan speed control, flame height
control, secondary burner On/OFF control and Accent Light ON/OFF controls will be manually controllable.
b. Normal Thermostat: In this mode, the fireplace will
stay functioning until the room temperature increases
o
1
F above the Set Point Temperature. To increase the
Set Point Temperature, Press the UP button until the
desired temperature is displayed in the SET POINT
TEMPERATURE window. The fan will turn on 5
minutes after fireplace startup and will turn off 12-1/2
minutes after the flames turn off, in this mode. The
flame height can be adjusted while the fireplace is func-
tioning, fan speed can be adjusted after 5 minutes of
startup. Secondary burner can be turned On or Off at
any time after startup. The Accent Light can be turned
on or off any time after startup.
c. Smart Thermostat: In this mode, all other functions
except the flame height adjustment are allowed. Manu-
al flame height adjustment is not allowed in this mode.
The Smart Thermostat function adjusts the flame height in accordance to the difference between the set point
temperature and the actual room temperature. As the room temperature gets closer to the set point temperature,
the Smart Function automatically modulates the flame down.
3. UP/DOWN KEY: This key is used to increase or decrease the Set Point Temperatures, Flame
Height and Fan Speed and to toggle between Accent Light ON/OFF and Secondary Burner
ON/OFF.
MODE SELECTION KEY: This key is used to toggle between the various function icons: Set Tem-
perature, Flame Height and Secondary Burner.

Setting Pilot to IPI versus CPI mode:

With the remote transmitter OFF, press the MODE button. You will see
either "CPI" or "IPI" displayed on the transmitter screen. Press the UP
arrow button to set "CPI" mode and press the DOWN arrow button to set
"IPI" mode. One set to the desired setting, press On/Off button to acti-
vate the fireplace.
OFF
76°
F
OFF
Hi
MAX
MANUAL
MODE
PAGE 30
SMART
ON
76°
F
ON
SMART
Hi
68
MAX
NORMAL
SMART
THERMOSTAT
MODE
76°
F

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fv44-d0616

Table of Contents