3 Handling

3.1

Transport

3.2

Storage

3.3

Assembly information

3.3.1

Mounting instructions

Checking system components
Geopress K repair coupling
Do not remove the connector from the packaging until
immediately before use.
Do not remove the connector from the packaging until
immediately before use.
Leave the protective caps in the connector until you are
ready to use it.
System components may, in some cases, become damaged through
transportation and storage.
Check all parts.
n
Replace damaged components.
n
Do not repair damaged components.
n
Inspect pipes visually for the following damage before installation:
Ovalities: threshold values must not be exceeded, see
n
tions from section: Notes on mounting" on page 8.
Dents
n
Cracks
n
Grooves (maximum depth 10 % of nominal wall thickness)
n
damaged pipe ends
n
Only process the sections of the pipes, which do not exhibit these fea‐
tures.