3 Handling
3.1
Assembly
3.1.1
Replace gas pressure spring
Gas pressure spring ≤ 28 kg
The model replaces the built-in gas pressure spring in the case of a
defect.
NOTICE!
Damage to the cover plate!
If the upper edge of the finished floor is higher than
planned, there is a risk that the cover plate will touch. To
avoid touching, limit the lowering of the WC (possible up to
a max. of 20 mm):
– Place a maximum of five 4 mm spacer washers under
the piston rod of the gas pressure spring.
Requirements:
The WC ceramic is at the lowest position.
n
Following components are removed:
n
–
WC ceramic
–
Cover plate
–
Actuating button / Hydraulic actuation
–
cover frame
Remove the gas pressure spring by unscrewing the top and bottom
5 mm Allen screw.
Handling
7 from 10