Maintenance Table; Air Quality Check; Single Stage Filter/Regulator Maintenance - QED AutoPump AP-3 Operation Manual

Table of Contents

Advertisement

AP-3 Manual

Maintenance Table

A visual check and/or maintenance is recommended at least once every two weeks, but
some site environments may demand more frequent service. The following table outlines the
recommended minimum schedule for the AP-3 System.
Equipment

Air Quality Check

• Single Stage Filter/Regulator
AutoPump Service
Check Pump Cycle Counter
Check Volume Pumped Per Cycle
* Site conditions may require maintenance more often.
The following sections describe each maintenance activity in detail.
Air Quality Check

Single Stage Filter/Regulator Maintenance

Even using air which has some oil and water in it, the AutoPump System should operate
trouble-free for years. The air filter is normally a 5 micron filter with a replaceable
element.
To replace the element in the air filter on the single stage filter/regulator use the following
procedure:
STEP
1 -
Disconnect Air Source
Valve off the air supply and drain the downstream air to the air filter.
Or disconnect the blue system air supply hose from the single stage
filter/regulator. The air filters will depressurize, allowing them to be
safely serviced.
WARNING:
Do not remove a filter bowl that is pressurized.
Page 44
Biweekly
Monthly*
X
X
QED Environmental Systems
As Required
X