INSTALLATION
Conduit Installation
• Purchase a squeeze connector
matching the diameter of the conduit
and assemble it in the hole. Insert the
conduit through the squeeze connector
and tighten. Allow enough slack to easily
attach the wires to the terminal block.
1. Remove the terminal block cover (on
the back of the range) by removing
the screw as described in
terminal block
discard screw.
2. Determine the size of conduit needed
and if necessary remove the conduit
plate or reverse the plate so that the
proper size opening in conduit plate for
your conduit is directly over the 1-3/8 in.
opening in the range bracket.
Caution: Retain this plate for future
!
use in case the range is moved and re-
wired.
3. Secure the power cord with using
squeeze connector as shown in figure.
4. For 3 or 4 wire power connection
installations follow next instructions.
1 Terminal block
2 Grounding screw
3 Range bracket
4 Squeeze connector
5 Power cord
22
Access to
instructions. Do not
3 & 4-wire permanent wire connections
Warning: For 3-wire permanent
!
connection read carefully and follow
steps 2 and 5 below.
Warning: For 4-wire permanent
!
connection read carefully and follow all
steps in the instructions below.
1. Follow the manufacturer's Installation
Instructions supplied with the strain
relief clamp and install.
2. Strip insulation away from the ends
of the permanent wiring for line 1, line
2 and neutral; also strip ground wire
on 4-wire connections. Tighten all 3
or 4-wire leads to the terminal block.
Follow wire locations shown in .
Warning: Do not loosen the factory
!
installed at connections which secure
the range wiring to the terminal block.
Electrical failure or loss of electrical
connection may occur if these 3 nuts
are loosened or removed.
For 3-wire permanent connection skip
i
steps 3 and 4 and continue with step 5.
3. Disconnect the grounding wire. Remove
the factory installed grounding screw
and plate to release the factory installed
grounding wire from frame of the
range. Cut and discard the grounding
wire from the terminal block. KEEP the
grounding screw, grounding wire and go
to step 4.
4. Connect the green grounding wire
lead to the frame of the range using
the grounding screw. Be sure to install
using the same hole in the frame where
the grounding screw was originally
installed.
5. Make sure all connections are tightened
securely and replace the rear access
cover. see
Access to terminal block
Warning: Non-terminated field wire
!
compression connections must be set
at approximately 90 in./lbs.
.