MedeScan BPS01 User Manual

MedeScan BPS01 User Manual

Smart blood pressure monitor

Advertisement

Quick Links

Fully Automatic Upper Arm
Smart Blood Pressure Monitor
Model Number: BPS01
info@medescan.com.au
USER'S MANUAL
Version Number:1.0

Advertisement

Table of Contents
loading

Summary of Contents for MedeScan BPS01

  • Page 1 Fully Automatic Upper Arm Smart Blood Pressure Monitor Model Number: BPS01 info@medescan.com.au USER’S MANUAL Version Number:1.0...
  • Page 2: Table Of Contents

    CONTENTS 1.Introduction and intended use............2.Important information on blood pressure and its measurement..3. Components of your blood pressure monitor........4. Using your monitor for the first time..........5.Measurement procedure..............6.Care and maintenance..............7. Warranty / service................8. Certifications..................9. Technical specifications..............10.
  • Page 3: Introduction And Intended Use

    The use of other accessories other than those specified or provided by the equipment manufacturer may cause The Medescan Smart BP Monitor enables reliable measurement of systolic electromagnetic radiation to increase or decrease electromag- and diastolic blood pressure as well as pulse through the oscillometric netic immunity resulting in operational failure method.
  • Page 4: Important Information On Blood Pressure And Its Measurement

    Technical Specifications. Note: The cuff is specially designed for the Medescan Smart Blood 2.2. Which values are normal? Pressure Monitor. The user should contact the manufacturer Please refer to the diagram below (Picture-01) for assistance, if needed, in setting up, using or maintaining the device.
  • Page 5: Components Of Your Blood Pressure Monitor

    There are six levels graded and shown on the display of device. Please refer 3.2 Identifying what You See on your LED Display to the table below. Different levels represent different interval scales according to the WHO. 1 2 3 4 5 6 7 8 PULES /min Picture-03...
  • Page 6: Using Your Monitor For The First Time

    4.2. System Settings 4. Using your Monitor for the First Time After you load the battery or connect power for the monitor,long press the 4.1 Using batteries for power SET button for more than 3s, and then you can start to set. Battery Installation Setting the Year: Use only 1.5V “AA”...
  • Page 7: Measurement Procedure

    5. Measurement Procedure 5.1. Before measurement: • Avoid eating and smoking as well as all forms of exertion directly before measurement. These factors may influence the measurement result. Please relax and be calm for approximatley 10 minutes before the measurement. •...
  • Page 8 fluctuation in the pressure 5.4. Irregular Heartbeat Detector The pressure that the sensor Er 7 Please contact Medescan Customer service sensing is over the limit This symbol - indicates that certain pulse irregularities were detected during the measurement. The calibration is incorrect or the In this case, the result may deviate from your normal blood pressure –...
  • Page 9 Cuff leaking Check if cuff is broken / ripped Change to new cuff Please contact Medescan Customer Service team on 1300 736 330 for any queries or 5.6. Memory unresolved issues. Each unit stores 120 sets measurements for 2 users, totally 240 memory sets SYMBOL DESCRIPTIONS (User A and B).
  • Page 10: Care And Maintenance

    Batteries and electronic instruments must be disposed of in accordance with the locally applicable regulations, not with domest`ic waste. 6.1. Accuracy test Sensitive measuring devices may need to be checked for accuracy from time to time. Please contact Medescan customer service if you have doubt about the measurements obtained.
  • Page 11: Warranty/Service

    fields, near the unit. This may result in incorrect operation of the unit. Caution: This unit has been thoroughly tested and inspected to assure Model: BPS01 proper performance and operation! Weight: 256g (Batteries and AC adapter are optional and may not be included) Display: 62.5*63.5mm【2.46"x2.5"】LED Digital Display...

Table of Contents