York ZV-06 Installation Manual page 4

Table of Contents

Advertisement

5567611-BIM-B-1218
Nomenclature
Product Category
Z = A/C, Single Pkg., R-410A
V = Pkg AC R410A Ultra High Eff
C = Cooling Only
E = Electric Heat
N = 2 Stage Gas Aluminized Steel
S = 2 Stage Gas Stainless Steel
E = VFD/VAV Std Static
G = VFD/VAV High Static
H = VFD/VAV w/Bypass Std Static
K = VFD/VAV w/Bypass High Static
P = VFD IntelliSpeed Std Static
R = VFD IntelliSpeed High Static
S = VFD w/Byp IntelliSp Std Static
U = VFD w/Byp IntelliSp Hi Static
4
3-12.5 Ton Model Number Nomenclature
Z
V
-06 C
Product Identifier
Nominal Cooling Capacity
-06 = 6.5 Ton
-07 = 7.5 Ton
-08 = 8.5 Ton
-10 = 10 Ton
-12 = 12.5 Ton
Heat Type
Two Stage Natural Gas Heat Options
Heat Capacity
00 = Cooling Only
Gas MBH Input (Unit Size Allowed)
18 = 180 MBH Input
24 = 240 MBH Input
Electric Heat (Unit Size Allowed)
09 = 9 KW (-06, -07, -08)
18 = 18 KW (-06,-07,-08,-10,-12)
24 = 24 KW (-06,-07,-08,-10,-12)
36 = 36 KW (-06,-07,-08,-10,-12)
54 = 54 KW (-10,-12)
Blower Option
A = No Economizer
B = Economizer w/Barometric RLF
D = Economizer w/Power EXH
H = Motorized Damper
00
A 2 A 1
A
A = No Sensors
B = PHM (Phase Monitor)
C = DFS (Dirty Filter Switch)
D = SSD (Supply Air Smoke DET)
E = RSD (Return Air Smoke DET)
F = PHM,DFS
G = PHM,SSD
Voltage
H = PHM,RSD
2 = 208/230-3-60
J = DFS,SSD
4 = 460-3-60
K = DFS,RSD
L = SSD,RSD
M = PHM,DFS,SSD
Outdoor Air Option
N = PHM,DFS,RSD
P = PHM,SSD,RSD
Q = DFS,SSD,RSD
R = PHM,DFS,SSD,RSD
1 = No Service Options
2 = DSC (Disconnect Switch)
3 = NCO (Non-PWR Conv. Outlet)
4 = PCO (Powered Conv. Outlet)
5 = DSC,NCO
6 = DSC,PCO
A
A 1
A 1
Product Generation
1 = First Generation
2 = Second Generation
Cabinet Options
A = Std Cabinet
E = SSD (SST Drain Pan)
R = Reverse Drain Pan
Additional Options
1 = STD Throwaway Filter
2 = 2" Pleated Filters (Merv 8)
3 = 4" Pleated Filters (Merv 13)
4 = Coil Guard (CG), STD Filter
5 = 2" Pleated Filter,CG
6 = 4" Pleated Filter,CG
Refrigeration
A = Standard Refrigeration
B = ECC (E-Coat Cond Coil)
C = EEC (E-Coat Evap Coil)
E = REH (Reheat)
F = ECC, EEC
G = ECC, EEC, HGBP
H = ECC, EEC, REH
J = ECC, HGBP
L = ECC, REH
M = EEC, HGBP
P = EEC, REH
Controls Option
A = Stand Alone Smart Equipment™
C = BACnet MSTP,Mdbs,N2 COM Card
D = CPC Control, DFS, APS
F = Fault Detection Diagnostics
G = Novar UCM Ctrl, DFS, APS
H = Hnywll Excel 10 CTRL,DFS,APS
M = Verasys Single Zone
N = Verasys Change Over Bypass
P = Verasys VAV
Q = Verasys Single Zone W/FDD
R = Verasys COBP W/FDD
T = Verasys VAV W/FDD
Sensors