Water Supply Off Temp. During Cooling - LG THERMA V HN0613T Installation Manual

Air-to-water heat pump
Table of Contents

Advertisement

Water supply off temp. during cooling

Determine the leaving water temperature which blocks the flow into underfloor coil in cooling
mode. This function is used for preventing condensation on the floor in cooling mode
• In the installer setting list, select Water supply off temp. during cooling category, and press
[OK] button to move to the detail screen.
Stop temp.
h Value is in °C
NOTE
• If the FCU is not used, the stop temp. cannot be set.
• Depending on FCU setting, the water cooling set temperature range is adjusted.
Value
Default
FCU
OK
OK
Range
Use
Use / Not use
16
25 ~ 16
INSTALLER SETTING
147