Installer Setting - LG THERMA V HN0613T Installation Manual

Air-to-water heat pump
Table of Contents

Advertisement

Installer setting

• You can set the product user functions.
• Some functions may not be displayed/operated in some product types.
Configuration
Function
Select Temperature Sensor
Use Heating Tank Heater
Mixing Circuit
Use External Pump
RMC master/slave
LG Therma V Configuration
General
Function
Forced operation
Pump Prerun/Overrun
Water Flow Control
Energy Monitoring
Anti-Freezing Option 1
Password Reset
Selection for setting temperature as air temperature or water
temperature or air+water temperature.
Determine the delay time of the electric heater for the water
tank.
This function is to use mixing circuit function. Set
enable/disable mixing circuit function and valve closing time and
hysteresis.
Set up to control an external water pump.
This function is to set master / slave to use two remote
controllers in one indoor unit.
This function can be set to save the environment settings of the
product for use in LG Therma V Configurator through Micro SD
card. (LG heating configurator)
Main water pump off After 20 consecutive hours, disable /
enable the logic that drives the water pump by itself.
Set to reach the optimum flow rate by circulating the heating
water with the water pump before heat exchange. After the
operation stop, additional water pump is activated to circulate
the heating water.
Set water pump to control the water flow.
Set up to use energy monitoring function of unit
This function is to select whether to use Type1 or Type2 to
prevent freezing when the remote control is turned off.
It is the function to reset (0000) the password when you forgot
the password set in the remote controller.
INSTALLER SETTING
Description
Description
117