Installation & Operation Manual D 314 05/11 tN2 Wiring Center 314 Zoning Replaces: 11/10 Introduction ® The tekmarNet 2 Wiring Center 314 is designed to operate up to four zone pumps in a hydronic heating system. It provides a convenient location to wire both thermostats and zone pumps while only requiring two wires to be run back to the mechanical room.
Physical Dimensions Front View Side View Back View 1/2” Knock-out (x 4) tN2 tN2 tN2 tN2 tN2 tN2 tN2 tN2 H8004C Zone 1 Zone 2 Zone 3 Zone 4 For use with Power tN2 thermostats only End Switch 5–1/2” (140 mm) tN2 Wiring Center 314 Four Zone Pumps 7/8”...
The control requires an external transformer with 20 VA VA, and includes an in-line fuse to protect the transformer capacity or greater. A tekmar Transformer 009 (or 009K and control. which includes a 4” x 4” electrical box) can supply up to 40...
Page 5
T-T (or R-W) terminals on the boiler. and R terminals marked “Input Power” on the 314. • If required, use the X X End Switch terminals to switch 24 V (ac) to power a demand on a tekmar outdoor reset tekmarNet ® 2 Thermostats control.
314. on and off, there may be a fault on the thermostat. 6. Replace the damaged wires, test, and reconnect them If a fault is suspected, contact your tekmar sales representative to their proper terminals. for assistance.
® 4 Expansion to House Control A314-1 Description: tN2 Wiring Center 314, four tekmarNet ® 2 Thermostats, and four zone pumps wired into a tekmar tN2 House Control 401 which controls the boiler and DHW pump. tekmarNet ® tekmarNet ®...
Page 8
Description: tN2 Wiring Center 314, four tekmarNet ® 2 Thermostats, and four zone pumps wired into a powered boiler demand input on a device such as a tekmar Boiler Control 260 which controls the boiler and DHW pump. tekmarNet ®...
Page 9
End Switch (X-X) To Boiler Enable (T-T) A314-3 Description: tN2 Wiring Center 314, four tekmarNet ® 2 Thermostats, and four zone pumps wired into the T-T terminals on the boiler to give an enable. tekmarNet ® 2 Thermostats tekmarNet ® 2 Thermostats Outdoor Sensor 070 tN2 tN2 tN2 tN2 tN2 tN2 tN2 tN2...
This can provide a boiler demand on. Power is then supplied to the appropriate zone output to a tekmar reset control, or provide a boiler enable to a as indicated by the LED. boiler’s TT terminals.