Model 560XL
DUAL GTC (TOUCH SCREEN CONTROLLER) FAILURE
1. TOUCH CTRL 1 (PRIM) Circuit Breaker (LH Panel – AVIONICS) – IN.
2. TOUCH CTRL 1 (SEC) Circuit Breaker (RH Panel – AVIONICS) – IN.
3. TOUCH CTRL 2 Circuit Breaker (RH Panel – AVIONICS) – IN.
IF DUAL GTC FAILURE REMAINS:
4. TOUCH CTRL 1 (PRIM) Circuit Breaker (LH Panel – AVIONICS) – PULL.
5. TOUCH CTRL 1 (SEC) Circuit Breaker (RH Panel – AVIONICS) – PULL.
6. TOUCH CTRL 2 Circuit Breaker (RH Panel – AVIONICS) – PULL.
7. Use the remote PFD controllers (GCU) to tune radios and control other functions.
Speaker volume control and on/off selection will not be functional.
The remote PFD controllers can be used to edit the flight plan and load procedures.
The MFW windows cannot be changed.
The remote PFD controllers can be used for range control and panning on the outboard
MFWs.
With the PFDs in FULL screen mode, the inset maps are available and can be controlled
using the PFD softkeys.
The transponder code cannot be changed.
Procedure completed
190-02313-03 Rev. 8
FAA Approved
Section III – Operating Procedures
Abnormal Procedures
Textron Aviation Citation 560XL
3-43