WBC6KIT Parts List ................4 Instructions ................... 4 Creating Thread Holes for the Protective Guard ........5 Assembly of WBC5KIT/WBC6KIT Guard ..........5 Installation of WBC5KIT/WBC6KIT Guard ........... 6 Attaching Water Hose Assembly To Loc-Line ........7 Hook & Loop Strap Installation ............. 8 Installation of EasyOn-EasyOff Sleeve ..........
GFCI Plug (120V) 140003 Hook & Loop Strap INsTruCTIoNs Alpha Professional Tools provides the highest quality parts and manufacturing techniques ® in the manufacture of this product. In order to obtain the maximum effectiveness and provide the highest degree of safety, it is necessary to review and follow these instructions carefully...
Hole Size: 5mm or #8 Drill Bit Illustration of Protection Guard 10mm (3/8”) 25mm (1”) assemBly of WBC5KIT/WBC6KIT Guard STEP 1 STEP 2 Thread Plastic Tie through the Place Loc-Line Assembly between drilled holes in the Safety Guard. the holes on the Safety Guard and...
INsTallaTIoN of WBC5KIT/WBC6KIT Guard Select the collar that is compatible for the make and model of the grinder (Refer to the Compatibility Chart) Plastic collar Stainless Steel collar Place the collar on the neck of the grinder. Position the Safety Guard over the collar with the shield facing backwards. Push Down until the Safety Guard is firmly seated on the base of grinders neck.
aTTaChING WaTer hose assemBly To loC-lINe Bend the Loc-Line Assembly to conform to the Water Hose Assembly. Attach and tighten the Adapter on the end of the Loc-Line. Attach and tighten the Water Hose Assembly onto the Adapter.
hooK & looP sTraP INsTallaTIoN Place the grinder on top of the Hook & Loop Strap. Position the Hook & Loop Strap around the Water Hose Assembly and the grinder body. NOTE: Position the strap away from the vent ports of the grinder. INsTallaTIoN of easyoN-easyoff sleeVe Wrap the EasyOn-EasyOff Sleeve around the Water Hose Assembly and electrical cord. Finish the wrapping procedure until the entire EasyOn-EasyOff sleeve is secured.
INsTallaTIoN of GfCI Install the GFCI to the grinders power cord as shown. Connect to power and check the GFCI for proper function. TesTING IN-lINe GfCI uNIT Connect GFCI to a single phase AC power supply Verify that the indicator lens shows red (indicating output voltage) Press the test button to verify that the red in the indicator lens disappears Press the reset button to verify the red indicator is visible The GFCI is now ready to use...
INsTallaTIoN of QuICK CoNNeCT adaPTer Secure the Quick Connect Adapter to the Water Hose Assembly. ComPleTed assemBly helPful hINT The spray nozzle can be easily adjusted to direct the proper amount of water distribution onto the blade based on the operator’s cutting application.