Fan Speed setting
To control the speed of the fan, press the FAN SPEED button. There are two fan
speeds which are low or high; each time the FAN SPEED button is pressed, the
speed of the fan toggles between these two speeds. Note that the fan speed can
not be set while in the LAUNDRY mode.
Swing Louver
To make the air outlet louver open and close continually, press the SWING button.
Pressing the SWING button again disables this function.
Child Lock function
To prevent accidental operation of the Main Unit, the control panel can be locked.

AUTO RESTART FUNCTION

If the Main Unit is unplugged or if there is a power failure, the Main Unit will resume
operation with the previous settings after power is restored.

WATER TANK FULL AUTO-STOP FUNCTION

When the water tank is full, the Main Unit will stop operation, the air outlet louver
will close and a buzzer will sound. To reset, remove the water tank, empty and
replace. When the empty water tank is put back into the Main Unit, it will restart.
Note that the compressor will take about 3 minutes to operate.

AUTO-DEFROST FUNCTION

If the Main Unit is used in a low temperature environment, the internal evaporator
may be covered by frost. In order to make sure the Main Unit operates normally, the
Main Unit has Auto-defrost function. Should the internal sensor detect a
temperature of ≤-1 °C the Main Unit will enter Auto-defrost function. That means it
will run continuously in the DEHUMIDIFY mode for 30 minutes, then the Main Unit
will start the defrost cycle, the DEFROST Indicator will illuminate, the compressor
will stop and that fan will operate at high speed.
When temperature of evaporator is ≥2 °C and the Main Unit has been in the defrost
cycle for 10 minutes, the Auto-defrost function will turn off and the compressor
turns on. At this point the Main Unit will start to dehumidify and the DEFROST
Indicator will turn off.
While in the defrost cycle and the temperature of the evaporator is ≥0 °C for two
minutes, the Auto-defrost function is canceled.

COMPRESSOR PROTECTION FUNCTION

Should there be a problem with the Main Unit causing the compressor to stop, the
compressor will turn off for 3 minutes. Normally the compressor will restart after 3
minutes, if it does not unplug the Main Unit for an hour and try again. If it still does
not start, call for service.