168

Energy state

This function is to control the product according to the energy state. When the charged state of
ESS is transmitted, it changes the target temperature of heating, cooling and DHW by setting
value according to energy state.
Select either Signal Mode or Modbus Mode according to the connection type between the
product and the ESS.
When Signal Mode of EES use type is selected, press the Digital Input Assignment button to set
the energy state according to the input signal.
Value
X
X
0:1
1:1
OK
OK
Input Signal
ES1
ES2
0
0
1
0
0
1
1
1
Output state
Default
Range
ES2
fixed
ES1
fixed
ES3
ES3-ES8
ES4