Disposing of the Filters

6. Replace the cover, and fasten the clips.
Disposing of the Filters
The combined filter is manufactured from non-toxic materials. Filters are not re-usable. The
method of disposal of the used filters depends on the material deposited on them.
It is the customer's responsibility to verify that the disposal of filters complies with all local
and/or industrial regulations.

System Specifications

Capacity: 75 m³/h (44 CFM)
Weight: 10.5 kg (23.1 lbs)
Fan type: Centrifugal
Power: 100 W
Voltage: 100-230 VAC
Frequency: 50/60 Hz
Full Load Current: 3.0 A
Noise Level: Below 57 dBA (at typical operating speed)
Overvoltage category: II
Maximum altitude: 2000 m (6561 ft.)
Allowable voltage input fluctuation: +/-10%
Control cable: 22-48 VDC input, 20 mA
Operating temperature range: +5 °C to + 40 °C (41 °F to 104 °F)
Operating humidity range:
Do not activate the system without a filter.
Warning: Hazardous Materials
When replacing the filter always wear a mask, safety shoes, goggles, and gloves.
Warning: Lifting Hazard
The filter weighs 25 Kg (55 lbs) and could cause injury if lifted improperly. Use proper
lifting techniques.
Max 80% Relative Humidity up to 31 °C (88 °F)
Max 50% Relative Humidity at 40 °C (104 °F)