Download Print this page

E2S IS-CP4A-PT Instruction Manual page 6

Tool reset manual call point for use in flammable gas and dust atmospheres

Advertisement

UKCA Declaration of Conformity
Manufacturer:
Equipment Type:
Directive UKSI 2016:1107 (as amended by UKSI 2019:696) – Schedule 3A, Part 1 : Product or Protective System Intended for use in Potentially Explosive Atmospheres
(UKCA)
Notified Body for UK type Examination (Module B):
UK-type Examination Certificate (Module B):
Notified Body for Quality Assurance Notification / Conformity to EU-type
based on
quality assurance of the production process (Module D):
Quality Assurance Notification (Module D):
Provisions fulfilled by the equipment:
Standards applied:
Directive 2014/30/EU: Electromagnetic Compatibility Directive (EMC)
Standards applied:
Directive 2011/65/EU: Restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS)
The product and all the components contained within it are in accordance with the restriction of the use of hazardous substances in electrical and electronic
equipment, including amendment by Directive 2015/863/EU.
Regulation (EC) 1907/2006: Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH)
The product and all the components contained within it are free from substances of very high concern.
Other Standards and Regulations
EN 60529:1992+A2:2013 - Degrees of protection provided by enclosures (IP code) – enclosure rated IP66
Construction and design requirements according to EN54-11:2001 clause 4.7 – IS-CP4A-BG / B-BG only (fitted with burning house symbol shown in figure 3a and no
lift flap)
E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sales@e2s.com www.e2s.com
European Safety Systems Ltd.
Impress House, Mansell Road, Acton
London, W3 7QH
United Kingdom
IS-CP4A, IS-CP4B, BExCP5B
Sira Certification Service
Notified Body No.: 0518
Rake Lane, Eccleston, Chester CH4 9JN, UK
CSAE 21UKEX2555X
Sira Certification Service
Notified Body No.: 0518
Rake Lane, Eccleston, Chester CH4 9JN, UK
CSAE 22UKQAN0046
IS-CP4A:
II 1G Ex ia IIC T6 Ga (-40°C ≤ Ta ≤ +55°C)
II 2D Ex tb IIIC T60°C Db (-40°C ≤ Ta ≤ +55°C)
IP6X Dust Protection to EN60079-0 / EN60079-31
IS-CP4B:
II 1G Ex ia IIC T4 Ga (-40°C ≤ Ta ≤ +55°C)
BEx-CP5B:
II 2D Ex tb IIIC T70°C Db (-40°C ≤ Ta ≤ +50°C)
IP6X Dust Protection to EN60079-0 / EN60079-31
EN IEC 60079-0:2018
EN 60079-11:2012
IEC 60079-26:2014
EN 60079-31:2014
EN 61000-6-1:2007
EN 61000-6-2:2005
EN 61000-6-3:2007 / A1:2011 / AC: 2012
EN 61000-6-4:2007 / A1: 2011
DC-091_Issue_A (IS-CP4)A- Page 1 of 2 - QAF_252_Issue_5