Majestic SA42R Installation Manual
Hide thumbs Also See for SA42R:
Table of Contents

Advertisement

Quick Links

INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
This fireplace uses SL300 Series Chimney
2" CLEARANCE TO COMBUSTIBLES AND BUILDING INSULATION FROM CHIMNEY REQUIRED.
NOTICE:
DO NOT discard this manual!
Model(s):
WOODBURNING FIREPLACE
Installation and service of this appliance should be performed by
Majestic Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev K • 1/22
Installation Manual
Installation and Fireplace Setup
WARNING: If the information in these
instructions is not followed exactly, a fire
or explosion may result causing property
damage, personal injury, or death.
• DO NOT store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
• DO NOT overfire. Overfiring will void your
warranty.
• Comply with all minimum clearances to com-
bustibles as specified. Failure to comply may
cause house fire.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fireplace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other flammable
materials.
• Keep clothing, furniture, draperies and other flammable
materials away.
WARNING
Fire Risk.
For use with solid wood fuel only.
Other fuels may overfire and generate
poisonous gases (i.e. carbon monoxide).
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SA42R and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Majestic SA42R

  • Page 1 Installation and service of this appliance should be performed by WARNING Fire Risk. For use with solid wood fuel only. Other fuels may overfire and generate poisonous gases (i.e. carbon monoxide). Majestic Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev K • 1/22...
  • Page 2: Table Of Contents

    C. Secure Offset/Return D. Install Ceiling Firestops E. Install Attic Insulation Shield F. Roof Penetration G. Install Chase/Chase Top H. Termination Cap Requirements I. Install Termination Cap Majestic Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev K • 1/22...
  • Page 3 Comments: Further description of the issues, who is responsible (Installer/Builder/Other Trades, etc.) and corrective action needed: Comments communicated to party responsible __________________________ by ______________________on _________ (Builder/Gen. Contractor) (Installer) (Date) 4010-261 • Rev A • 2-5-15 Majestic Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev K • 1/22...
  • Page 4: Product Specific & Important Safety Information

    State of California to cause birth defects or other reproductive harm. For more infor- mation go to: www. P65Warnings.ca.gov. Majestic Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev K • 1/22...
  • Page 5: Getting Started

    Decorative facing (1.22 m) off and trim ground level. Hearth extension Outside combustion air Factory-built fireplace Protective metal hearth strip(s) Figure 2.1 Typical Fireplace System Majestic Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev K • 1/22...
  • Page 6: Design And Installation Considerations

    Minimum from FP 1295 1092 1902 1346 opening to any 77 1/2 38 7/8 54 7/8 SA42 perpendicular wall. 1448 1245 1969 1394 Figure 2.2 Fireplace Locations Majestic Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev K • 1/22...
  • Page 7: Locating Fireplace & Chimney

    • Avoid outside wall in cooler climates Windward Leeward Not recommended in basement due Figure 2.3 Recommended Chimney Locations to high negative pressure concerns that effect draft Majestic Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev K • 1/22...
  • Page 8: Tools And Supplies Needed

    Report to your dealer any parts damaged in shipment. • Read all the instructions before starting the installation. Follow these instructions carefully during the installation to ensure maximum safety and benefit. Majestic Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev K • 1/22...
  • Page 9: Framing And Clearances

    (108 mm) 13-1/2 in. 13-1/2 in. (343 mm) (343 mm) Model # 28-1/4 14-1/8 SA36 1067 30-7/8 15-1/2 SA42 1067 1219 ► Figure 3.1 Appliance Dimensions Majestic Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev K • 1/22...
  • Page 10: Clearances

    (except at nailing flanges 48 in. where it is 1/2 in. [13 mm]) 1219 mm 0 in. to floor Figure 3.2 Clearances to Combustible Materials Majestic Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev K • 1/22...
  • Page 11: Construct The Chase

    Figure 3.3. This will help reduce heat loss from the home around the fireplace. Majestic Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev K • 1/22...
  • Page 12: Frame The Fireplace

    * If interior of chase will be drywalled, add the thickness to this measurement. ** Adjust header height for a raised floor under fireplace. Figure 3.5 Framing the Fireplace Majestic Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev K • 1/22...
  • Page 13: Protective Metal Hearth Strips

    Floor instructions. 2 in. (51 mm) Nail or screw metal strips in place. Figure 3.7 Protect the Front of an Elevated Platform Majestic Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev K • 1/22...
  • Page 14: Outside Air Kit (Optional)

    • Secure flex duct with screws or wire ties. Figure 3.8 Outside Air Installation Figure 3.10 Outside Air Installation with Cold Air Trap Majestic Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev K • 1/22...
  • Page 15: Chimney And Termination Requirements

    16.5 ft (5.03 m) min. height/single offset-return (1051 mm) 20 ft. (6.10 m) min. height/double offset-return Effective 90 ft (27.4 m) max. height Height Figure 4.1 Chimney Requirements Majestic Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev K • 1/22...
  • Page 16: Offsets/Returns

    Proper assembly of air-cooled chimney parts result in an overlap at chimney joints of 1-1/4 in. (32 mm). Effective length is built into this chart. Majestic Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev K • 1/22...
  • Page 17: Termination Requirements

    In a staggered installation with both gas and wood terminations, the wood termination cap must be higher than the gas termination cap. Figure 4.3 Multiple Chimney Locations Majestic Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev K • 1/22...
  • Page 18: Chimney Installation

    2 inch through ceiling or clearances. floor Figure 5.1 Typical Chimney System - Guidelines for Chimney System Installation Majestic Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev K • 1/22...
  • Page 19: Assemble Chimney Sections

    Vertical straight runs of chimney must be supported every 35 ft (10.7 m). Figure 5.2 Assembling Chimney Sections WARNING! Risk of Fire! DO NOT install substitute or damaged chimney components. Majestic Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev K • 1/22...
  • Page 20: Secure Offset/Return

    • Use an attic insulation shield if the ceiling is insulated. The ceiling firestop may then be attached above or below the joists. Majestic Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev K • 1/22...
  • Page 21: Install Attic Insulation Shield

    If they have been connected correct- ly, they will not disengage when tested. Figure 5.7 Install Attic Insulation Shield (firestop below ceiling) Majestic Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev K • 1/22...
  • Page 22: Roof Penetration

    WARNING! Risk of Fire! DO NOT caulk the pipe to the chase top collar. • Caulk all seams to prevent leaks. .018 (26 ga) min. Galvanized Chase Top Figure 5.9 Chase Top Construction Majestic Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev K • 1/22...
  • Page 23: Termination Cap Requirements

    1-1/2 in. (38 mm). Figure 5.12 Installing an ST375 Square Termination Cap Figure 5.10 Installing a TR344 Round Termination Cap Majestic Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev K • 1/22...
  • Page 24 2 in. (51 mm) Chase Top 4-3/4 in. (121 mm) Chase Chimney Pipe Figure 5.15 Installing CT-3A-B Cap Adapter Figure 5.15 Installing a DTO134/DTO146/DTS134/DTS146 Cap Majestic Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev K • 1/22...
  • Page 25: Shrouds

    3 in (76 mm) air space from bottom of shroud Chase Top to top of chase. Figure 6.3 Shroud & TR Series cap with no Radiation Shield Majestic Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev K • 1/22...
  • Page 26: Mailbox Style Shroud

    Min. Base Dims. 27 x 27 Min. Opening Width 686 x 686 Min. Height Above Bottom of Termination Cap Min. Opening Width Min. Opening Height Majestic Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev K • 1/22...
  • Page 27: Finishing

    2 in. (51 mm) ► Figure 7.2 Decorative Facing Majestic Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev K • 1/22...
  • Page 28: Hearth Extension, Building And Finishing

    14-5/8 in. - 20-3/8 • Choose finishing materials carefully. Marble 14.3-20.0 0.07-0.05 Hearth Extension Dimensions Model # SA36 (HX3) 1321 SA42 (HX4) 1676 Figure 7.3 Hearth Extension Dimensions Majestic Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev K • 1/22...
  • Page 29: Fireplace Installed Flush On The Floor And Hearth Extension Raised To Bottom Of Firebox Opening

    110°F in a room with ambient tem- peratures of 70°F. Consult flooring specifications to Non-combustible ensure compatibility. Finishing Materials Figure 7.7 Raised Platform Hearth Extension-Finishing Majestic Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev K • 1/22...
  • Page 30: Raised Hearth Extension And Raised Fireplace

    Protective Metal Hearth Strips Non-combustible Floor and platform constructed of Framing Material wood or other combustible material Figure 7.8 Raised Hearth Extension and Fireplace Framing Materials Majestic Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev K • 1/22...
  • Page 31: Fireplace Opening And Hearth Extension Flush With The Floor

    Hearth Extension discoloration, cracking or other material failures of finishing materials due to heat exposure or smoke. • Choose finishing materials carefully. Micore Noncombustible Material Protective Metal Hearth Strip Figure 7.9 Flush Hearth Extension Side View Majestic Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev K • 1/22...
  • Page 32: Mantel And Wall Projections

    WARNING: Seal joint with non-combustible sealant to prevent heat from being drawn into the wall cavity. ► Figure 7.12 Mantel Specifications Majestic Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev K • 1/22...
  • Page 33: Sidewalls/Surrounds

    9 3/4 in. [248 mm] 12 in. 12 in. [305 mm] [305 mm] Figure 7.13 Mantel Leg, Surround or Wall Projection (acceptable on both sides of opening) Majestic Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev K • 1/22...
  • Page 34: Fireplace Setup

    WARNING! Do Not operate an unvented gas log set in this fireplace with the chimney removed. Majestic Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev K • 1/22...
  • Page 35: Reference Materials

    (305 mm) 5-1/4 in. Attic Shield Kit (133 mm) 4 in. (102 mm) 10-1/2 in. Attic Collar (287 mm) CAK4A Chimney Air Kit Attic Spacer Majestic Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev K • 1/22...
  • Page 36 24-5/8 in. 10-1/2 in. 31 in. (625 mm) (267 mm) (787 mm) CB876 Chimney Joint Band RF371 Roof Flashing TR-TVK TR Top Vent Kit CT-3A-B Majestic Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev K • 1/22...
  • Page 37 15-3/4 in. (400 mm) TR344 Round Termination Cap TS345/TS345P Square Termination Cap TR342-B Round Telescoping Termination Cap TCT375 Terra Cotta Cap ST375 Square Termination Cap Majestic Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev K • 1/22...
  • Page 38 21 3/16 in. (577 mm) (538 mm) 46 in. 46 in. (1168 mm) (1168 mm) 26 in. 26 in. (660 mm) (660 mm) DTO146 DTS146 Majestic Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev K • 1/22...
  • Page 39: Optional Components

    UD4 Uninsulated Duct 12.5 15.5 LDS-BV 4 in. (102 mm) i.d. 42 in. (1067 mm) See your HHT dealer for a complete list of optional components. Majestic Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev K • 1/22...
  • Page 40 Majestic, a brand of Hearth & Home Technologies 7571 215th Street West, Lakeville, MN 55044 www.majesticproducts.com Majestic Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev K • 1/22...

This manual is also suitable for:

Sa36rSovereign series

Table of Contents