Majestic SA36C Installation Manual

Majestic SA36C Installation Manual

Woodburning fireplace
Hide thumbs Also See for SA36C:

Advertisement

Quick Links

INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
7KLV ¿UHSODFH XVHV 6/ 6HULHV &KLPQH\
2" CLEARANCE TO COMBUSTIBLES AND BUILDING INSULATION FROM CHIMNEY REQUIRED.
NOTICE:
DO NOT discard this manual!
Model(s):
WOODBURNING FIREPLACE
Installation and sHUYLFH of this DSSOLDQFHshould EH performed Ey
Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev L • 01/22
Installation Manual
Installation and Fireplace Setup
WARNING: If the information in these
LQVWUXFWLRQV LV QRW IROORZHG H[DFWO\ D ¿UH
or explosion may result causing property
damage, personal injury, or death.
• DO NOT VWRUH RU XVH JDVROLQH RU RWKHU ÀDP-
PDEOH YDSRUV DQG OLTXLGV LQ WKH YLFLQLW\ RI WKLV
RU DQ\ RWKHU DSSOLDQFH
• DO NOT RYHU¿UH 2YHU¿ULQJ ZLOO YRLG \RXU
warranty.
‡ &RPSO\ ZLWK DOO PLQLPXP FOHDUDQFHV WR FRP-
EXVWLEOHV DV VSHFL¿HG )DLOXUH WR FRPSO\ PD\
FDXVH KRXVH ¿UH
WARNING
HOT SURFACES!
*ODVV DQG RWKHU VXUIDFHV DUH KRW GXULQJ
RSHUDWLRQ $1' FRRO GRZQ
Hot glass will cause burns.
• DO NOT WRXFK JODVV XQWLO LW LV FRROHG
‡ 1(9(5 DOORZ FKLOGUHQ WR WRXFK JODVV
‡ .HHS FKLOGUHQ DZD\
‡ &$5()8//< 683(59,6( FKLOGUHQ LQ VDPH URRP DV
¿UHSODFH
‡ $OHUW FKLOGUHQ DQG DGXOWV WR KD]DUGV RI KLJK WHPSHUDWXUHV
+LJK WHPSHUDWXUHV PD\ LJQLWH FORWKLQJ RU RWKHU ÀDPPDEOH
materials.
‡ .HHS FORWKLQJ IXUQLWXUH GUDSHULHV DQG RWKHU ÀDPPDEOH
materials away.
WARNING
Fire Risk.
For use with solid wood fuel only.
2WKHU IXHOV PD\ RYHU¿UH DQG JHQHUDWH
SRLVRQRXV JDVHV LH FDUERQ PRQR[LGH 
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SA36C and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Majestic SA36C

  • Page 1 Installation and sHUYLFH of this DSSOLDQFHshould EH performed Ey WARNING Fire Risk. For use with solid wood fuel only. 2WKHU IXHOV PD\ RYHU¿UH DQG JHQHUDWH SRLVRQRXV JDVHV LH FDUERQ PRQR[LGH  Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev L • 01/22...
  • Page 2: Table Of Contents

    & 6HFXUH 2 VHW5HWXUQ ' ,QVWDOO &HLOLQJ )LUHVWRSV ( ,QVWDOO $WWLF ,QVXODWLRQ 6KLHOG F. Roof Penetration * ,QVWDOO &KDVH&KDVH 7RS + 7HUPLQDWLRQ &DS 5HTXLUHPHQWV , ,QVWDOO 7HUPLQDWLRQ &DS Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev L • 01/22...
  • Page 3: Attention Installer

    Comments: )XUWKHU GHVFULSWLRQ RI WKH LVVXHV ZKR LV UHVSRQVLEOH ,QVWDOOHU%XLOGHU2WKHU 7UDGHV HWF DQG FRUUHFWLYH DFWLRQ QHHGHG Comments communicated to party responsible __________________________ by ______________________on _________ %XLOGHU*HQ &RQWUDFWRU ,QVWDOOHU 'DWH  ‡ 5HY % ‡  Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev L • 01/22...
  • Page 4: 3Urgxfw 6Shfl¿F

    State of California to cause birth defects or other reproductive harm. For more infor- mation go to: www.P65Warnings.ca.gov. Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev L • 01/22...
  • Page 5: Getting Started

    4 ft. and trim (1.22 m) off ground level. Hearth extension Outside combustion air Factory-built fireplace Protective metal hearth strip(s) Figure 2.1 Typical Fireplace System Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev L • 01/22...
  • Page 6 Minimum from FP 1295 1092 1902 1346 opening to any 77 1/2 38 7/8 54 7/8 SA42 perpendicular wall. 1448 1245 1969 1394 Figure 2.2 Fireplace Locations Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev L • 01/22...
  • Page 7: Rfdwlqj )Luhsodfh &Klpqh

    ‡ $YRLG RXWVLGH ZDOO LQ FRROHU FOLPDWHV :LQGZDUG /HHZDUG 1RW UHFRPPHQGHG LQ EDVHPHQW GXH WR KLJK QHJDWLYH SUHVVXUH FRQFHUQV )LJXUH  5HFRPPHQGHG &KLPQH\ /RFDWLRQV WKDW HIIHFW GUDIW Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev L • 01/22...
  • Page 8: Tools And Supplies Needed

    5HSRUW WR \RXU GHDOHU DQ\ SDUWV GDPDJHG LQ VKLSPHQW • Read all the instructions before starting the installation. Follow these instructions carefully during the installation to ensure maximum safety DQG EHQH¿W Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev L • 01/22...
  • Page 9: Framing And Clearances

    [51] [108] 13-1/2 13-1/2 [341] [341] Model # 28 1/4 14 1/8 SA36 1067 30 7/8 15 1/2 SA42 1067 1219 )LJXUH  $SSOLDQFH 'LPHQVLRQV Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev L • 01/22...
  • Page 10: Minimum Clearances To Combustibles

    (except at nailing flanges 48 in. where it is 1/2 in. [13 mm]) 1219 mm 0 in. to floor )LJXUH  &OHDUDQFHV WR &RPEXVWLEOH 0DWHULDOV Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev L • 01/22...
  • Page 11: Construct The Chase

    LQVXODWHG WR WKH OHYHO RI WKH IDOVH FHLOLQJ DV VKRZQ LQ )LJXUH  &KDVH &RQVWUXFWLRQV )LJXUH  7KLV ZLOO KHOS UHGXFH KHDW ORVV IURP WKH KRPH DURXQG WKH ¿UHSODFH Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev L • 01/22...
  • Page 12: Frame The Fireplace

    * If interior of chase will be drywalled, add the thickness to this measurement. ** Adjust header height for a raised floor under fireplace. )LJXUH  )UDPLQJ WKH )LUHSODFH Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev L • 01/22...
  • Page 13: Protective Metal Hearth Strips

    IRU KHDUWK H[WHQVLRQ Floor LQVWUXFWLRQV 2 in. (51 mm) Nail or screw metal strips in place. )LJXUH  3URWHFW WKH )URQW RI DQ (OHYDWHG 3ODWIRUP Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev L • 01/22...
  • Page 14: Outside Air Kit (Optional)

    • Secure flex duct with screws or wire ties. )LJXUH  2XWVLGH $LU ,QVWDOODWLRQ ZLWK &ROG $LU 7UDS )LJXUH  2XWVLGH $LU ,QVWDOODWLRQ Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev L • 01/22...
  • Page 15: Chimney And Termination Requirements

    16.5 ft (5.03 m) min. height/single offset-return (1051 mm) 20 ft. (6.10 m) min. height/double offset-return Effective 90 ft (27.4 m) max. height Height Figure 4.1 Chimney Requirements Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev L • 01/22...
  • Page 16: Vhwv5Hwxuqv

    3URSHU DVVHPEO\ RI DLUFRROHG FKLPQH\ SDUWV UHVXOW LQ DQ RYHUODS DW FKLPQH\ MRLQWV RI  LQ  PP  ( HFWLYH OHQJWK LV EXLOW LQWR WKLV FKDUW Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev L • 01/22...
  • Page 17: Termination Requirements

    In a staggered installation with both gas and wood terminations, the wood termination cap must be higher than the gas termination cap. )LJXUH  0XOWLSOH &KLPQH\ /RFDWLRQV Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev L • 01/22...
  • Page 18: Chimney Installation

    2 inch through ceiling or clearances. floor Figure 5.1 Typical Chimney System - Guidelines for Chimney System Installation Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev L • 01/22...
  • Page 19: Assemble Chimney Sections

    9HUWLFDO VWUDLJKW UXQV RI FKLPQH\ PXVW EH VXSSRUWHG HYHU\  IW  P  Figure 5.2 Assembling Chimney Sections WARNING! Risk of Fire! DO NOT install substitute or damaged chimney components. Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev L • 01/22...
  • Page 20: Install Ceiling Firestops

    ZKHQ WKHUH LV D URRP DERYH ‡ 8VH DQ DWWLF LQVXODWLRQ VKLHOG LI WKH FHLOLQJ LV LQVXODWHG 7KH FHLOLQJ ¿UHVWRS PD\ WKHQ EH DWWDFKHG DERYH RU EHORZ the joists. Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev L • 01/22...
  • Page 21: Install Attic Insulation Shield

    WR HQVXUH SURSHU HQJDJHPHQW EHIRUH LQVWDOOLQJ WKH VXF- FHHGLQJ VHFWLRQV ,I WKH\ KDYH EHHQ FRQQHFWHG FRUUHFW- O\ WKH\ ZLOO QRW GLVHQJDJH ZKHQ WHVWHG )LJXUH  ,QVWDOO $WWLF ,QVXODWLRQ 6KLHOG ¿UHVWRS EHORZ FHLOLQJ Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev L • 01/22...
  • Page 22: Roof Penetration

    WARNING! Risk of Fire! DO NOT caulk the pipe to the chase top collar. ‡ &DXON DOO VHDPV WR SUHYHQW OHDNV .018 (26 ga) min. Galvanized Chase Top Figure 5.9 Chase Top Construction Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev L • 01/22...
  • Page 23: Termination Cap Requirements

    1-1/2 in. (38 mm). )LJXUH  ,QVWDOOLQJ DQ 67 6TXDUH 7HUPLQDWLRQ &DS )LJXUH  ,QVWDOOLQJ D 75 5RXQG 7HUPLQDWLRQ &DS Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev L • 01/22...
  • Page 24 2 in. (51 mm) Chase Top 4-3/4 in. (121 mm) Chase Chimney Pipe )LJXUH  ,QVWDOOLQJ &7$% &DS $GDSWHU Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev L • 01/22...
  • Page 25: Shrouds

    3 in (76 mm) air space from bottom of shroud Chase Top to top of chase. )LJXUH  6KURXG 75 6HULHV FDS ZLWK QR 5DGLDWLRQ 6KLHOG Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev L • 01/22...
  • Page 26: Mailbox Style Shroud

    Min. Base Dims. Min. Opening Width  [   [  Min. Height Above Bottom of Termination Cap Min. Opening Width Min. Opening Height Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev L • 01/22...
  • Page 27: Finishing

    2 in. (51 mm) Figure 7.2 Decorative Facing Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev L • 01/22...
  • Page 28: Hearth Extension, Building And Finishing

    14 5/8 in. - 20 3/8 in. 0DUEOH ‡ &KRRVH ¿QLVKLQJ PDWHULDOV FDUHIXOO\ Hearth Extension Dimensions Model # 6$ +;  6$ +;  )LJXUH  +HDUWK ([WHQVLRQ 'LPHQVLRQV Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev L • 01/22...
  • Page 29: Vinyl Flooring

    VLRQ )ORDWLQJVW\OH ÀRRULQJ FDQ EH XVHG EXW ZLOO UHDFK WHPSHUDWXUHV XS WR ƒ) LQ D URRP ZLWK DPELHQW WHP- SHUDWXUHV RI ƒ) &RQVXOW ÀRRULQJ VSHFL¿FDWLRQV WR HQVXUH FRPSDWLELOLW\ Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev L • 01/22...
  • Page 30: Raised Hearth Extension And Raised Fireplace

    Protective Metal Hearth Strips Non-combustible Floor and platform constructed of Framing Material wood or other combustible material Figure 7.8 Raised Hearth Extension and Fireplace Framing Materials Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev L • 01/22...
  • Page 31: Non-Combustible Sealant Material

    Hearth & Home Technologies is not responsible for discoloration, cracking or other material failures of ¿QLVKLQJ PDWHULDOV GXH WR KHDW H[SRVXUH RU VPRNH ‡ &KRRVH ¿QLVKLQJ PDWHULDOV FDUHIXOO\ Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev L • 01/22...
  • Page 32: Mantel And Wall Projections

    WARNING: Seal joint with non-combustible sealant to prevent heat from being drawn into the wall cavity. )LJXUH  0DQWHO 6SHFL¿FDWLRQV Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev L • 01/22...
  • Page 33 9 3/4 in. [248 mm] 12 in. 12 in. [305 mm] [305 mm] )LJXUH  0DQWHO /HJ 6XUURXQG RU :DOO 3URMHFWLRQ DFFHSWDEOH RQ ERWK VLGHV RI RSHQLQJ Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev L • 01/22...
  • Page 34: Fireplace Setup

    UHOLQH DW WKH WRS RI WKH ÀXH DQG XVLQJ WKH FDS FHUWL¿HG IRU XVH ZLWK WKLV ¿UHSODFH V\VWHP WARNING! Do Not operate an unvented gas log set in this ¿UHSODFH ZLWK WKH FKLPQH\ UHPRYHG Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev L • 01/22...
  • Page 35: Reference Materials

    Storm Collar 7HUPLQDWLRQ &DS´ &7$% $GDSWHU  0D\ EH XVHG ZLWK WKH IROORZLQJ FDSV CT Series Attic Shield Kit DT Series Attic Collar Attic Spacer Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev L • 01/22...
  • Page 36 24-5/8 in. 31 in. (625 mm) 10-1/2 in. (787 mm) (267 mm) CB876 Chimney Joint Band 5) 5RRI )ODVKLQJ TR-TVK TR Top Vent Kit &7$% Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev L • 01/22...
  • Page 37 15-3/4 in. (400 mm) 75 5RXQG 7HUPLQDWLRQ &DS 76763 6TXDUH 7HUPLQDWLRQ &DS 75% 5RXQG 7HOHVFRSLQJ 7HUPLQDWLRQ &DS 7&7 7HUUD &RWWD &DS 67 6TXDUH 7HUPLQDWLRQ &DS Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev L • 01/22...
  • Page 38 21 3/16 in. (577 mm) (538 mm) 46 in. 46 in. (1168 mm) (1168 mm) 26 in. 26 in. (660 mm) (660 mm) DTO146 DTS146 Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev L • 01/22...
  • Page 39: Optional Components

    (1067 mm) LDS-BV Decorative Shroud UD4 Uninsulated Duct Catalog #   4 in. (102 mm) i.d. LDS-BV 42 in. (1067 mm) ). )DQ .LW Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev L • 01/22...
  • Page 40 0DMHVWLF D EUDQG RI +HDUWK +RPH 7HFKQRORJLHV  WK 6WUHHW :HVW /DNHYLOOH 01  ZZZPDMHVWLFSURGXFWVFRP Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev L • 01/22...

This manual is also suitable for:

Sa42c