TECHNICAL DATA

Dust Extraction
Production code
Rated input P
iec
Rate of air flow
Vacuum
Capacity:
Container
Solid
Liquid
Filter surface
Maximum power off-take
Safety class (Moisture, Dust)
Suction hose diameter
Weight according EPTA-Procedure 01/2003
D GB
Noise/Vibration Information
Measured values determined according to EN 60704-1. Typically, the A-weighted noise levels of the tool are:
Sound pressure level (Uncertainty K=2dB(A))
Sound level / Working sound level (Uncertainty K=2dB(A))
Wear ear protectors!
Total vibration values (vector sum in the three axes) determined according to ISO 5349.
Vibration emission value a
Uncertainty K=
WARNING!
Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may result in
electric shock, fire and/or serious injury.
Save all warnings and instructions for future reference.

SAFETY INSTRUCTIONS

This machine is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities, or lack
of experience and knowledge.
Children should be supervised to ensure that
they do not play with the appliance.
Fire and explosion hazard!
Never suck up into the machine any inflam-
mable or explosive solvents, or liquids like
petrol, oil, alcohol, thinners, or small particles
(such as metal filings or ash) that may be
hotter than 60°C - otherwise there is danger of
explosion or fire!
English
Deutsch
12
h
You are not allowed to use the appliance in the
vicinity of inflammable gases or substances.
Do not point the nozzle, hose or tube at
people or animals.

SPECIFIED CONDITIONS OF USE

The vacuum cleaners described in this operating manual are
suitable for
• sucking up dust and li quids
• commercial use, e.g. in hotels, schools, hospitals, factories,
shops, offices and rental businesses.
• for separation of dust with an exposure limit of greater than 1
mg/m³, (dust class L).
The following materials should not be picked up by the vacuum
cleaner
• hazardous dust
• hot materials (burning cigarettes, hot ash, etc.)
• flammable, explosive, aggressive liquids (e.g. petrol, solvents,
acids, alkalis, etc.)
• flammable, explosive dust (e.g. magnesium or aluminium dust,
etc.)
Any national regulations in this regard must be complied with.
AP 2-200 ELCP
(220-240 V)
4474 61 01...
... 000001-999999
1000 W
3600 l/min
216 m
/h
3
21 kPa / 210 mbar
24,6 l
21 l
18 l
3000 cm²
2600 W
IP24
32 mm
7,5 kg
72 dB (A)
64 dB A)
< 1,5 m/s
2
1 m/s
2