Komatsu PC390LC-10 Shop Manual page 38

Hydraulic excavator
Hide thumbs Also See for PC390LC-10:
Table of Contents

Advertisement

FOREWORD
9.
Push lock type (1)
95/107/114 series.
Examples: Fuel pressure sensor in common rail (BOSHCH-3)
A. Disconnection
i.
While pressing lock (C), pull out connector (3) in the direction of the arrow.
114 series
107 series
★ If the lock is located on the underside, use a flat-head
screwdriver [1] since you cannot insert your fingers.
While pressing up lock (C) of the connector with the flat-
head screwdriver [1], pull out connector (3) in the
direction of the arrow.
B. Connection
i.
Insert the connector straight until it "clicks."
c
00-22
HANDLING ELECTRIC EQUIPMENT AND HYDRAULIC COMPONENTS
PC360/390LC-10