CAUTION
1.
In quiet or stopping operation, slight flowing noise of refrigerant in the refrigerating cycle is heard occasionally,
but this noise is not abnormal for the operation.
2.
When it thunders near by, it is recommended to stop the operation and to disconnect the power cord plug
from the power outlet for safety.
3.
The room air conditioner does not start automatically after recovery of the electric power failure for preventing
fuse blowing. Re-press START/STOP button after 3 minutes from when unit stopped.
4.
If the room air conditioner is stopped by adjusting thermostat, or missoperation, and re-start in a moment,
there is occasion that the cooling and heating operation does not start for 3 minutes, it is not abnormal
and this is the result of the operation of IC delay circuit. This IC delay circuit ensures that there is no
danger of blowing fuse or damaging parts even if operation is restarted accidentally.
5.
This room air conditioner should not be used at the cooling operation when the outside temperature is
below 10°C (50°F).
6.
This room air conditioner (the reverse cycle) should not be used when the outside temperature is below
–10°C (14°F).
If the reverse cycle is used under this condition, the outside heat exchanger is frosted and efficiency falls.
7.
When the outside heat exchanger is frosted, the frost is melted by operating the hot gas system, it is not
trouble that at this time fan stops and the vapour may rise from the outside heat exchanger.
– 3 –