T
ROUBLESHOOTING
Continued from
Previous Page
With the gas supply shut off,
install a pressure tap on the
manifold in the plugged tap
Install a manometer
on the pressure tap.
Turn on the gas
supply to the range.
Re-light the pilots and turn
on all the burners.
Observe the manifold
pressure.
Manifold pressure are:
Natural gas = 4 in. water column
Propane gas = 10 in. water column
If the pressure is low, check the
incoming line for obstructions.
Shut off the burners and main gas
and remove the pressure tap.
Replace the pressure tap
plug in the manifold.
Re-light the pilots.
Install the grates or
griddle tops.
Toastmaster
®
provided.
M
D
EDIUM
Test each burner.
Each burner should have a
steady blue flame on each port
of the burner.
Propane burners may have a small
amount of yellow tipping. This is normal.
If the flame is rising up off of the ports
adjust the burner shutter closed.
If the flame is long and yellow
adjust the burner shutter open.
NOTE : Griddle burners may
be long and float when cold.
Allow the top to heat before
making burner adjustments.
Propane burners may have a
slight popping noise when
turned off. This is normal.
Reinstall the front
panel and knobs.
C
UTY
OUNTERLINE
P
AGE
20