M
D
C
EDIUM
UTY
OUNTERLINE
Common checks for all top
configurations.
Check that the burners are set
level in the support brackets.
Check that the burners are
clean and all ports are clear.
Remove each burner and check
that the venturi is clean and free
of buildup and debris.
With each burner removed check that
the orifice size is correct and clean and
free of buildup and debris.
Remove the knobs and carefully
lower the top valve cover panel.
Check that each burner valve and
orifice is in alignment with the burner.
Shut off the main gas supply.
Install a pressure tap in the main gas line
before the range pressure regulator and
install a manometer.
Turn on the main gas supply.
Re-light all pilots.
Light all burners on the range.
P
19
AGE
OPEN TOP BURNER
TROUBLESHOOTING.
NOTE : Griddle Tops
NOTE : Griddle must be raised
and secured or removed.
CAUTION! Before raising or
Remove the knobs and carefully
lower the top valve cover panel.
Inlet pressures for gases are:
Natural = 5 to 7 in. water column
Propane = 11 to 14 in. water column
If the inlet pressure is low, all equipment
on the main gas line should be lit and the
Shut off the range burners and
main gas and remove the
Continue on next page.
T
ROUBLESHOOTING
removing Griddle Tops.
Observe the inlet
pressure.
pressure adjusted.
pressure tap.