Transport; Installation; General Information; Sound Emissions - Dimplex SIH 20TE Installation And Operating Instruction

Brine-to-water heat pump for indoor installation

Advertisement

SIH 20TE
5

Transport

For the transport by means of a hand truck or boiler trolley, po-
sition the latter under the front end of the unit below the trans-
port security device.
For transport on a level surface, the unit can be lifted from the
rear or from the front by means of a lift truck or forklift. In this
case, the transport securing device is not imperative.
45°
CAUTION!
The heat pump must not be tilted more than max. 45° (in
either direction).
After the transport, the transport securing device is to be re-
moved on either side at the bottom of the unit.
CAUTION!
The transport securing device is to be removed prior to
commissioning.
To remove the panelling, open the individual covers by un-
screwing the respective turn-lock fasteners and then gently tilt-
ing the covers away from the device. Then lift them up out of
the mountings.
www.dimplex.de
Remove/screw in
transport lock
452234.66.77b · FD 0307
6

Installation

6.1 General Information

The brine-to-water heat pump must be installed in a frost-free,
dry room on an even, smooth and horizontal surface. The entire
frame should lie directly on the floor to ensure an adequate
soundproof seal. Failing this, additional sound insulation meas-
ures may become necessary.
The heat pump should be installed to allow easy maintenance/
service access. This is ensured if a clearance of approx. 1 m in
45°
front of the heat pump is maintained.
NOTE
The heat pump is not intended for use over 2000 metres
above sea level.
Neither frost nor temperatures higher than 35 °C must occur in
the installation location at any time of the year.

6.2 Sound Emissions

The heat pump offers silent operation due to efficient sound in-
sulation. Any vibration transmission to the foundation or the
heating system can be largely prevented by internal sound de-
coupling measures.
7

Mounting

7.1 General Information
The following connections need to be estab-lished on the heat
pump:
Flow and return of the brine (heat source system)
supply/return flow of the heating system
Temperature sensor
Voltage supply
English
0,5m
1m
EN-5