  • Page 1: Specifications

    N-8000 Network Intercom Systems Architectural and Engineering Specifications TOA Electronics, Inc. 601 Gateway Blvd., Ste. 300 So. San Francisco, CA 94080 1-650-588-2538 / 1-800-733-7088 www.toaelectronics.com  All Rights Reserved, 2005...
  • Page 2: Introduction

    This document is designed to help you easily specify the groundbreaking N-8000 Network Intercom System for your projects. If you need more information, please visit TOA on the web at http://www.toaelectronics.com where you’ll find specification sheets, manuals, CAD files, software and more! If you’d like a demonstration or a sample for evaluation, please contact a TOA Sales...
  • Page 3: Table Of Contents

    TOA Architectural and Engineering Specifications Table of Contents Introduction Table of Contents General Conditions and Requirements Manufacturer Contractor Qualifications Standard Products Service Facilities System Features General System Programming Dialing Station Numbering and Naming Standard Features (No Programming Required) Automatic Line Release...
  • Page 4 TOA Architectural and Engineering Specifications System Configuration and Components General System Size Connection of External Equipment Wiring Service Distances Exchange Components N-8000EX Exchange Unit N-8010EX Exchange Unit E-7000TB System Terminal Blocks Peripheral Interface Components N-8000MI Multi-Interface Unit Station Components N-8500MS IP Multifunction Master Station...
  • Page 5: General

    The equipment furnished under this specification shall be equal in every way to that manufactured by TOA Electronics Inc. Catalog and model numbers are intended to indicate type and quality of design and material, as well as exact operating features. All equipment shall be designed by the manufacturer to operate as a complete system, and shall be accompanied by the manufacturer's complete installation and operating instructions.
  • Page 6: System Programming

    TOA Architectural and Engineering Specifications System Programming System programming shall be accessible by the contractor, or the end user, to allow restructuring of the system as needed. System programming shall be accessible from a Windows PC computer on the same Ethernet network as the intercom exchange, running the dedicated setup software.
  • Page 7: Ambient Noise Control

    TOA Architectural and Engineering Specifications Ambient Noise Control A Master Station shall be able to automatically adjust its voice switching threshold to compensate for ambient noise when a designated key is pressed. Selectable Features (Enabled Through Programming) Paging and Response The system programming shall allow stations to be grouped into paging zones.
  • Page 8: Group Blocking (Restricted Dialing)

    TOA Architectural and Engineering Specifications Station dialing numbers shall be independent of connected exchange number or • other hardware configuration. Station numbering shall be programmable as two to six digits in length. Paging Zone Numbering shall be programmable as single, double or triple digit.
  • Page 9: Annunciation

    1 to 9 seconds. Install N-8050DS Door Station(s) as required. BGM (Background music) The system shall allow connection of up to eight BGM sources, and assigned Master Stations shall be able to access any of these sources. Install TOA N-8000MI Multi-Interface Unit(s) as required. External audio source distribution The system shall allow distribution of audio from external sources to system paging zones.
  • Page 10: System Configuration And Components

    TOA Architectural and Engineering Specifications System Configuration and Components General System Size The intercom Exchange Unit shall support 16 station ports and 2 paging audio outputs (N- 8000EX only). Connecting exchanges to a local area or wide area IP network (10BASE- T/100BASE-TX) shall permit the establishment of multiple-exchange systems supporting up to a maximum of 1280 station ports and a maximum of 160 paging zones.
  • Page 11: E-7000Tb System Terminal Blocks

    ABS resin, with a dust proof rubber key pad. The IP Multifunction Master Station shall be the TOA N-8000MS. The optional 120 VAC power supply shall be the TOA AD-1210P. The optional wall-mount bracket shall be the TOA YC-280.
  • Page 12: N-8000Ms Multifunction Master Station

    The station shall be capable of being desk or wall mounted and shall be constructed of ABS resin, with a dust proof rubber key pad. The Hands-Free Master Station shall be the TOA N- 8011MS. The optional wall-mount bracket shall be the TOA YC-290.
  • Page 13: N-8050Ds Door Station

    The Flush- Mount Master Station shall be the TOA N-8031MS. The optional handset shall be the TOA RS- 191. The optional flush-mount backbox shall be the TOA YC-241. The optional surface-mount backbox shall be the TOA YC-251.