DECLARATION OF CONFORMITY SUMAKE INDUSTRIAL CO., LTD. 4F, No. 351, Yangguang St., Neihu District, Taipei City, Taiwan declare in sole responsibility that the equipment Equipment: PRESSURE AIR SPRAY GUN W/O CUP (FOR PRESSURE TANK USE) Model/ Serial No.: SS-1140P to which this declaration applies, complies with these normative documents: Machinery Directive: 2006/42/EC ...
Page 3
INSTRUCTION MANUAL FAULTY PATTERNS AND HOW TO CORRECT THEM PROBLEM CAUSE SOLUTION GUN HANDLING Top heavy or bottom heavy pattern: The first requirement for a good resultant finish is the proper handling of the gun. The gun Material buildup on air cap, partially Soak cap or tip in suitable solvent and plugged horn holes, center hole or jets.
SS-1140P PRESSURE AIR SPRAY GUN, W/O CUP PARTS LIST Parts No. Description Q'ty Parts No. Description Q'ty 1140P 01 1140P-01 Air Cap / Retaining Ring 1 6 Air Cap / Retaining Ring -1.6 1140P 15 1140P-15 Fl id Needle 1 6 Fluid Needle -1.6...
The tool has been manufactured in conformity with the instruction of EU machine directive. The EU mark will be considered void in the event of inexpert repairs, the use of non-original parts and in case of non-observance of the safety instructions in the user’s manual. Possible direct or indirect consequential damages are not the responsibility of SUMAKE Industrial co., Ltd. General safety rules: Watch the tool at all times when in use.
Page 7
Safety precautions for repetitive motions hazards 1. When using the tool, the operator may experience discomfort in the hands, arms, shoulders, neck, or other parts of the body. 2. While using the tool, the operator should adopt a comfortable posture. Maintain secure footing and avoid awkward or off-balanced postures.
General preparation and connection: Before connecting the air hose, apply 4 to 5 drops of SAE#10-20 spindle oil at the air inlet. Also, every 3 to 4 hours of operation, oiling is necessary. Twist Teflon thread tape to ensure a proper seal air inlet. Then tighten the air coupler into air tool. The supplied compressed air must be clean and dry, with the appropriate oil mist.
Need help?
Do you have a question about the SS-1140P and is the answer not in the manual?
Questions and answers