To close the drain holes and attach the drain socket

6.3.6 To prevent the outdoor unit from falling over

2MXM68+3(A)MXM+3(A)MXF+4MXM+5MXM
R32 Split series
4P600463-1D – 2021.03
1 Install drain caps (accessory f) and (accessory g). Make sure the edges of the
drain caps close off the holes completely.
2 Install the drain socket.
a
b
c
b
a Drain hole. Install a drain cap (large).
b Drain hole. Install a drain cap (small).
c Drain hole for drain socket
In case the unit is installed in places where strong wind can tilt the unit, take
following measure:
1 Prepare 2 cables as indicated in the following illustration (field supply).
2 Place the 2 cables over the outdoor unit.
3 Insert a rubber sheet between the cables and the outdoor unit to prevent the
cables from scratching the paint (field supply).
4 Attach the ends of the cables.
5 Tighten the cables.
b
a
a
6
Unit installation
|
Installer reference guide
31